SESAME SB-9000 electric bolt lock
- Model
- 9398
All-metal electric bolt lock for steel gates and heavy doors: 2000 kg holding force, key cylinder and IP55 protection for outdoor use.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Holding force
- 304 stainless steel, 2000 kg holding force
- Power supply
- DC12 V or DC24 V (need order)
- Dimensions
- 329.5L × 41 W × 46H (mm)
- Door type
- Steel gates; Heavy door
Description
The SESAME SB-9000 is a reinforced all-metal electric bolt lock for steel gates and heavy doors. Control is twofold: electric, from the access control system, and manual, with a key in the European-profile cylinder.
- 304 stainless steel bolt, CNC-turned: 17.8 mm in diameter, 29.5 mm throw, 2000 kg holding force.
- Fail-secure: the door stays locked without power.
- Solenoid tested to 1 million cycles.
- Rain-proof design and IP55 rating for indoor and outdoor installation.
- NC/NO/COM lock status output.
- Mounting with the bolt throwing left or down.
- CE marked.
Power
12 V DC, or 24 V DC to order. At 12 V the start-up current is 5.0 A and standby 0.6 A; at 24 V, 3.0 A and 0.35 A. The high start-up current calls for a dedicated power supply.
Body 329.5 × 41 × 46 mm, 1.8 kg. Power calculation and the mounting point on the gate are part of access control installation.
Specifications
| Certifications | CE |
|---|
| Lock behaviour on power loss | Fail secure |
|---|---|
| Holding force | 304 stainless steel, 2000 kg holding force |
| Lock status sensor | Lock signal: NC/NO/COM |
| Power supply | DC12 V or DC24 V (need order) |
|---|---|
| Current draw | Start 12 V/5.0 A; Standby 12 V/0.6 A; Start 24 V/3.0 A; Standby 24 V/0.35 A |
| Dimensions | 329.5L × 41 W × 46H (mm) |
|---|---|
| Net weight | 1.8 kg |
| Material | 304 stainless steel |
| Mounting | Can be installed to the left or down |
| Ingress protection (IP) | IP-55 |
| Door type | Steel gates; Heavy door |
| Bolt size | 29.5(prolongation)*17.8(diameter)(mm) |
Used in solutions
FAQ
Why is door closer needed in Access Control System?
Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.
How to choose correct closer for door weight?
Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.
Can door closer integrate with fire alarm?
Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.