Fire alarm installation
Fire alarms for offices, hotels, schools, warehouses and homes: smoke, heat and gas detectors, control panels, call points and alerts to your phone.
What's included
Detector layout
Using the floor plan, we choose the type and position of each detector, taking ceiling height and ventilation into account.
Loop wiring
We lay cable in trunking or concealed in the walls, and connect detectors, call points and sounders to the control panel.
Standalone detectors for homes
We fit battery-powered smoke and gas detectors and interconnect them so that the alarm sounds throughout the house.
Alerts to your phone
We connect the detectors to the app through a gateway and check that alarms get through.
Testing every point
We test detectors, call points and sounders, and show you how to use the control panel.
LAGI's fire alarm installation in Tbilisi starts with the floor plan: the area, ceiling height and use of each room determine how many detectors are needed and of what type. In offices and hotels we install a system with a control panel, detection loops and manual call points; in apartments and private houses, interconnected standalone smoke detectors are often enough. An engineer visits the site free of charge, looks at the rooms and proposes a detector layout. The requirements that apply to your type of building are clarified at the design stage.
Addressable or conventional system
| Conventional | Addressable | |
|---|---|---|
| What the panel shows | The zone, for example ‘floor 2’ | The exact detector: ‘room 204’ |
| Cable | A separate circuit for each zone | One loop for many detectors |
| Equipment | A cheaper panel and detectors | A more expensive panel and detectors, but less cable in a large building |
| Where it fits | A small office, shop, café, house | A hotel, business centre, school, hospital |
For small premises a conventional system is enough, and it is simpler to maintain. In a building with dozens of rooms, an addressable system is quicker to work with: the person on duty sees straight away which room the smoke is in and does not have to check the whole floor.
Which detectors go where
- Smoke detector – in bedrooms, corridors, offices and on escape routes. Mounted on the ceiling, away from air conditioners and ventilation.
- Heat detector – in the kitchen, boiler room and garage, where steam, cooking smoke or exhaust fumes would cause false alarms with a smoke detector.
- Gas detector – next to the gas cooker and boiler. A natural gas detector is mounted high, because methane is lighter than air, and an LPG detector low, near the floor.
- Carbon monoxide detector – in rooms with a gas boiler, gas water heater or fireplace.
- Manual call point – by the exits, so that anyone who sees a fire can raise the alarm themselves.
Equipment we install
Most systems are built on Heiman detectors. Heiman optical smoke detectors are certified to the European standard EN 14604, with a loud signal of 85 dB or more. The range includes models with a 10-year battery and models that can be interconnected by wire or radio: if smoke appears in one room, the alarm sounds in all of them. For panel-based systems there are Heiman conventional wired detectors and control panels. We also install heat detectors, gas detectors, carbon monoxide detectors, alarm buttons and alarms for people with impaired hearing, with a strobe and vibration.
Through a Heiman gateway, the detectors are connected to an app: alarms come to your phone, and you can test or silence a detector remotely and see which one was triggered.
Alerts and evacuation
In buildings with many people, a siren alone is not enough: a voice message is needed to tell people which way to go out. This voice alarm is linked to the fire alarm through a PA and sound system, so that when the alarm goes off, music in the building stops and a recorded announcement is played.
What affects the price
- The floor area, number of rooms and ceiling height.
- The system type: standalone detectors, conventional or addressable.
- The length of the loops and how the cable is laid.
- Voice alarm, and links to access control and ventilation.
The site survey in Tbilisi is free, and after it you receive an estimate. You can request a quote on our website.
Sites we work on
A fire alarm is needed in offices, hotels and guesthouses, schools and kindergartens and warehouses. For a private house, interconnected standalone smoke detectors and a gas detector by the boiler are usually enough. For a large building the system is designed first: see our security system design page.
Warranty and maintenance
LAGI gives a warranty on the equipment and the installation work: the terms are set out in the contract, and the general conditions are on our warranty page. A fire alarm needs regular checks: dust builds up in the detectors and batteries run down. We check the detectors and the control panel as part of our maintenance service.
How it goes
- 01
Free site survey in Tbilisi
We inspect the rooms, ceiling heights and escape routes, and discuss the system type.
- 02
Layout and estimate
We prepare a layout of detectors and call points, an equipment list and an estimate.
- 03
Installation
We lay the loops and install the control panel, detectors, call points and sounders.
- 04
Testing and training
We check that every detector triggers, and train staff in what to do when the alarm goes off.
- 05
Regular maintenance
We test and clean the detectors and replace detector and panel batteries.
Equipment for this service
Products we install as part of this service.
Questions & answers
How much does fire alarm installation cost?
The price depends on the floor area, the number of rooms, the system type and the loop lengths. Standalone smoke detectors for an apartment cost far less than an addressable hotel system with a control panel, call points and voice alarm. We give the exact figure after a survey or from a floor plan. The site survey in Tbilisi is free.
Which smoke detector should I fit in an apartment?
A standalone optical smoke detector certified to EN 14604. A detector of this type needs no control panel: power comes from a battery, and the loud alarm sounds from the detector itself. Models with a 10-year battery are convenient. If the apartment has several rooms, choose detectors interconnected by radio, so that all of them sound at once.
Where should smoke detectors go?
On the ceiling of every bedroom, the hallway and the living room, towards the centre of the room. Not next to an air conditioner, extractor hood or window, where the airflow carries smoke away. In a two-storey house, a detector is needed on each floor and above the stairs. In the kitchen, a heat detector is fitted instead of a smoke detector.
Why does a fire alarm go off for no reason?
Most often because of the wrong position: cooking sets off a smoke detector by the cooker, steam one near the bathroom, and cigarette smoke one in a smoking area. Another cause is dust and insects inside the detector. That is why detectors are chosen to suit the room and cleaned periodically, and dusty renovation work is done with the detectors covered.
Where should gas and carbon monoxide detectors go?
A natural gas detector goes high up, under the ceiling near the cooker or boiler: methane is lighter than air and rises. A detector for bottled LPG goes low, near the floor. A carbon monoxide detector is placed in the room with the boiler, gas water heater or fireplace, and in the bedroom, at breathing height or as the model's instructions specify.
Can I get fire alerts on my phone?
Yes. Heiman detectors are connected to an app through a gateway, and when a detector is triggered, a notification naming it is sent to your phone. In the app you can test or silence a detector remotely. The gateway needs Wi-Fi with internet access for this. Without the internet, the detectors still work and the alarm still sounds on site.
Other services
Not sure what you need?
Book a free site survey in Tbilisi: an engineer walks the property with you and suggests a setup.