Skip to content

Fire Alarm Systems & Life Safety Equipment

Categories

Products

38 products

  • Heiman HM-920 alarm control panel
    Power supply
    AC220 V±15%/50 Hz
    Dimensions
    300 × 210 × 100 mm
    Zones
    2 zones / 4 zones

    Price on request

  • Heiman HM-5HA standalone heat detector
    Sensor type
    Thermistor
    Sensor life
    10 years
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Built-in

    Price on request

  • Heiman HM-638TH combined smoke and carbon monoxide detector
    Sensor type
    Photoelectric
    Power supply
    Power supply: AC100-240 V with backup Sealed battery; Power supply mode: 10 years Battery Built-in
    Interconnection
    Standalone/Hardwire Inter-linked (optional)

    Price on request

  • Heiman HM-633PH smoke detector
    Sensor type
    Photoelectric
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 1 year Battery (Hardwire Inter-linked); 5 years Battery (Hardwire Inter-linked); 10 years Battery Replaceable (Standalone RF433 RF868)
    Wireless protocol
    RF433, RF868

    Price on request

  • Heiman HM-638PH smoke detector
    Sensor type
    Photoelectric
    Power supply
    Power supply: AC100-240 V with backup Sealed battery; Power supply mode: 10 years Battery Built-in
    Wireless protocol
    RF868

    Price on request

  • Heiman HM-626PH standalone smoke detector
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Built-in
    Interconnection
    Standalone
    Sound level
    ≥85 dB (at 3 m)

    Price on request

  • Heiman HS1SA standalone smoke detector
    Sensor type
    Photoelectric
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Replaceable
    Interconnection
    Standalone

    Price on request

  • Heiman HM2SA-1 standalone smoke detector
    Sensor type
    Photoelectric
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery (Built-in/Replaceable)
    Wireless protocol
    RF433, RF868

    Price on request

  • Heiman HM-635PH smoke detector
    Sensor type
    Photoelectric
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 1 year Battery (Hardwire Inter-linked); 5 years Battery (Hardwire Inter-linked); 10 years Battery Replaceable (Standalone RF433 RF868)
    Wireless protocol
    RF433, RF868

    Price on request

  • Heiman HM-726N gas detector
    Detected gas
    Ch4
    Compatible devices
    Solenoid Valve Manipulator
    Power supply
    AC 100-240 V

    Price on request

  • Heiman S1 standalone smoke detector
    Sensor type
    Photoelectric
    Alarm threshold
    1.625%/FT ± 0.625%/FT
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Replaceable

    Price on request

  • Heiman HM1RC remote controller
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 1 year Battery
    Wireless protocol
    RF433, RF868
    Dimensions
    34.5 × 57.5 × 13 mm

    Price on request

  • Heiman HM-625PH standalone smoke detector
    Sensor type
    Photoelectric
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Built-in
    Interconnection
    Standalone

    Price on request

  • Heiman HM2SA-5 standalone smoke detector
    Sensor type
    Photoelectric
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery (Built-in/Replaceable)
    Wireless protocol
    RF433, RF868

    Price on request

  • Heiman HM-710N gas detector
    Alarm threshold
    6%±3% LEL
    Compatible devices
    Electromagnetic valve
    Power supply
    AC 100-240 V

    Price on request

  • Heiman HM3RC remote controller
    Maximum connected devices
    40
    Card frequency
    868.3 MHz / 433 MHz
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Built-in

    Price on request

  • Heiman HM-628PH standalone smoke detector
    Sensor type
    Photoelectric
    Power supply
    Power supply: DC 9 V Battery; Power supply mode: 1 year Battery; 5 years Battery
    Interconnection
    Standalone

    Price on request

  • Heiman HM-205 standalone heat detector
    Sensor type
    Thermistor
    Alarm threshold
    Class: A1; Alarms at temperature range: 54 °C to 65 °C
    Maximum connected devices
    40

    Price on request

  • Heiman HM2RC remote controller
    Power supply
    Power supply: DC3 V (Lithium Battery); Power supply mode: 3 years Battery
    Wireless protocol
    RF433, RF868
    Dimensions
    Φ62.4 × 14.3 mm

    Price on request

  • Heiman HM-805 PIR motion detector
    Detection range
    12 m
    Sensor type
    Microwave & Infrared, Infrared
    Detection angle
    90 degrees

    Price on request

We install it too

Delivery, installation, setup and warranty service from LAGI.

See the installation service

Need a price for your property?

Describe the property and what needs protecting. We will send you the cost of equipment and installation.

Fire Alarm Systems – Life Safety in Tbilisi

Fire Alarm Systems are critical safety systems for early fire detection and saving lives in residential and commercial properties in Tbilisi and throughout Georgia. These systems detect smoke, fire, high temperature, carbon monoxide (CO), and gas leaks at the initial stage of fire and immediately alert with loud siren, visual signal, and automatically contact fire service, allowing timely evacuation and preventing loss of life and major property damage. LAGI offers a full range of fire alarm equipment: optical smoke detectors (photoelectric sensor, 85dB sound), ionization smoke detectors for fast-flaming fires, heat detectors 57°C/72°C temperature, carbon monoxide (CO) detectors, gas detectors CH4/LPG, conventional fire panels 2-32 zones, addressable systems 512+ detectors, Manual Call Point buttons, sirens and strobes 100dB sound. All systems comply with Georgian fire safety standards and international EN54 certification.

Main Components of Fire Alarm Systems

  • Smoke detectors – optical (photoelectric) and ionization types, 85dB sound, 1-10 year battery life, test button.
  • Heat detectors – respond to temperature 57°C/72°C, ideal for kitchens, garages where smoke detectors are not suitable.
  • Carbon monoxide (CO) detectors – detect colorless deadly gas, 85dB sound, LCD screen for CO level display, 7-10 year lifespan.
  • Gas detectors – detect natural gas (CH4) and liquefied gas (LPG), 85dB sound, relay output for gas valve closure.
  • Fire panels – conventional (2-32 zones) and addressable (512+ detectors), LCD screen, battery backup power, BMS integration.
  • Manual Call Point – manual activation buttons (break glass), red color, installation at exits, 470Ω resistor.

Questions & answers

How often should fire detectors be tested?

Fire detectors should be tested monthly by pressing the test button (should sound alarm). Batteries should be replaced annually or when detector starts beeping (low battery). Entire detector should be replaced every 10 years (sensor degrades over time). Professional inspection should be conducted annually.

What's the difference between conventional and addressable fire systems?

Conventional systems – detectors grouped into zones (e.g. zone 1 = first floor), panel shows only which zone alarmed, cheaper, suitable for small sites. Addressable systems – each detector has unique address, panel shows exactly which detector activated (e.g. "smoke detector #47, 3rd floor, room 305"), more expensive, mandatory for large buildings.

Can fire alarms integrate with other systems?

Yes, fire alarms integrate with: access control (automatic door opening during evacuation), ventilation systems (smoke extraction, fire spread prevention), elevator control (elevator descends to first floor and locks), video surveillance (automatic recording), BMS building management systems (centralized monitoring).