SESAME SC-280/SC-280-S concealed magnetic lock
- Model
- 9338
Concealed magnetic lock with 280 kg holding force and a door status signal output, for glass, wooden and metal doors.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Holding force
- 280 kg (600lb)
- Dimensions
- 250 × 47 mm (lock); 160 × 43 mm (armature plate)
Description
The SESAME SC-280 is a concealed magnetic lock with 280 kg holding force. The 250 × 47 mm body and the 160 × 43 mm armature plate sit flush in the frame and leaf, with nothing protruding from the door.
For glass, wooden, metal and fire doors.
- Door status signal output for the access controller.
- Holding by the electromagnet alone, with no mechanical assemblies.
- Built-in varistor (MOV) for reverse-current protection at switch-off.
- Aluminium alloy body with hard anodising, double insulation.
Holding force is matched to the weight and use of the door during access control installation.
Specifications
| Holding force | 280 kg (600lb) |
|---|
| Dimensions | 250 × 47 mm (lock); 160 × 43 mm (armature plate) |
|---|---|
| Mounting | Conceal Mounted |
Used in solutions
FAQ
Why is door closer needed in Access Control System?
Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.
How to choose correct closer for door weight?
Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.
Can door closer integrate with fire alarm?
Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.