Skip to content
SESAME

SESAME SC-350/SC-350-S concealed magnetic lock

Model
9389

Concealed magnetic lock with 350 kg holding force: 250 × 50 mm body, door status signal and MOV protection.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Holding force
350 kg (800lb)
Dimensions
250 × 50 mm (lock); 160 × 43 mm (armature plate)
All specifications

Description

The SESAME SC-350 is a concealed magnetic lock with 350 kg holding force: the 250 × 50 mm body is recessed into the door frame and the 160 × 43 mm armature plate into the leaf. Suitable for glass, wooden, metal and fire doors.

  • Door status signal, so the access controller knows whether the door is closed.
  • No mechanical parts: holding is fully electromagnetic.
  • Built-in varistor (MOV) for reverse-current protection.
  • Aluminium alloy body, hard anodised, double-insulated.

The lock, controller and exit button are chosen together as part of access control installation.

Specifications

Access control
Holding force350 kg (800lb)
Physical and environment
Dimensions250 × 50 mm (lock); 160 × 43 mm (armature plate)
MountingConceal Mounted

FAQ

Why is door closer needed in Access Control System?

Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.

How to choose correct closer for door weight?

Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.

Can door closer integrate with fire alarm?

Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.

Need it installed?

LAGI will deliver, install and set up the equipment and provide warranty service afterwards.