SESAME SE-2NO/SE-2NC electric strike
- Model
- 9372
Electric strike with a 250 × 25 mm face plate and 500 kg holding force: 12 V DC, NO (fail-secure) and NC (fail-safe) versions.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Power supply
- 12VDC
Description
The SESAME SE-2NO/SE-2NC is an electric strike with a long 250 × 25 × 31 mm face plate. The strike is fitted in the door frame opposite the latch of a mechanical lock; on a command from the access controller the latch is released.
- NO version, fail-secure: locked without power. NC version, fail-safe: the door opens when power is cut.
- 500 kg holding force.
- 12 V DC power, current draw up to 450 mA.
- Aluminium body, stainless steel bolt.
- Tested to 100000 cycles, CE marked.
The face plate length is checked against the frame profile during access control installation.
Specifications
| Certifications | CE |
|---|
| Lock behaviour on power loss | FAIL SECURE (NO); FAIL-SAFE (NC) |
|---|
| Power supply | 12VDC |
|---|---|
| Current draw | 450 mA; 200 mA |
| Lock panel size | 250L × 25 W × 31H (mm) |
|---|
Used in solutions
FAQ
Why is door closer needed in Access Control System?
Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.
How to choose correct closer for door weight?
Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.
Can door closer integrate with fire alarm?
Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.