Skip to content
SESAME

SESAME SE-6NC-S electric strike

Model
9366

Electric strike with 1000 kg holding force and an NO/NC/COM lock status output, so the controller knows whether the lock is engaged.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Power supply
12VDC or 24VDC (need order)
All specifications

Description

The SESAME SE-6NC-S is an electric strike with 1000 kg holding force and a lock status output (NO/NC/COM): from this signal the access controller or alarm system can tell whether the door is locked.

The strike goes into a metal frame in place of the mechanical lock's strike plate, fitted in a drilled hole. The mode is switchable: NO (fail secure) keeps the door locked without power, NC (fail safe) lets the door open when power is removed.

  • 12 or 24 V DC, voltage set at order; 320 mA at 12 V, 160 mA at 24 V.
  • Adjustable distance to the mechanical lock's latch.
  • 123 × 43 × 42 mm, 0.34 kg.
  • Tested to 100000 cycles, high-temperature paint finish, CE certified.

The sensor output is wired to a controller input during access control installation.

Specifications

General
CertificationsCE
Access control
Lock behaviour on power lossFail secure or Fail safe (NO & NC adjustment)
Lock status sensorNO/NC/COM
Power
Power supply12VDC or 24VDC (need order)
Current draw12 V/320 mA; 24 V/160 mA
Physical and environment
Lock panel size123L × 43 W × 42H (mm)
Net weight0.34 kg

FAQ

Why is door closer needed in Access Control System?

Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.

How to choose correct closer for door weight?

Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.

Can door closer integrate with fire alarm?

Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.

Need it installed?