Skip to content
SESAME

SESAME SE-7-S electric strike

Model
9365

Electric strike for doors with a European standard mechanical lock: switchable fail safe or fail secure, with lock, door and bolt sensor outputs.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Power supply
12 V/320 mA (24 V need order)
Dimensions
174L × 44 W × 27H (mm)
Door type
European Standard Mechanical Lock
All specifications

Description

The SESAME SE-7-S is an electric strike for doors with a European standard mechanical lock: fitted in the frame in place of the strike plate, with a solenoid drive. The mode is switchable: fail safe (the door opens without power) or fail secure (the door stays locked without power).

  • NO/NC/COM outputs for the lock sensor and door sensor, so the controller sees whether the door is closed and the lock engaged.
  • Separate bolt signal with NO/NC/COM contacts.
  • Pin in hardened 304 stainless steel.
  • 12 V power, 320 mA; a 24 V version to order.
  • 174 × 44 × 27 mm, 0.5 kg, CE certified.

The sensor signals are wired to the controller and the alarm system during access control installation.

Specifications

General
CertificationsCE
Access control
Lock behaviour on power lossFail Safe / Fail Secure adjustable
Lock status sensorSignal output: Lock sensor & Door sensor (NO/NC/COM); Bolt signal: With NO/NC/COM contacts
Power
Power supply12 V/320 mA (24 V need order)
Physical and environment
Dimensions174L × 44 W × 27H (mm)
Net weight0.5 kg
Pin materialHarden 304 Stainless Steel
Door typeEuropean Standard Mechanical Lock

FAQ

Why is door closer needed in Access Control System?

Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.

How to choose correct closer for door weight?

Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.

Can door closer integrate with fire alarm?

Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.

Need it installed?

LAGI will deliver, install and set up the equipment and provide warranty service afterwards.