SESAME SE-8LKNO-S/SE-8LKNC-S electric strike
- Model
- 9359
Electric strike with 1000 kg holding force: 12 V DC at 320 mA or 24 V DC at 160 mA, in fail-secure and fail-safe versions.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Holding force
- 1000 kg
- Power supply
- DC12 V or DC24 V
- Operating temperature
- -10 °C – +55 °C (14-131F)
- Door type
- Wooden door/Metal door/Glass door/PVC door
Description
The SESAME SE-8LKNO-S/SE-8LKNC-S is an electric strike with 1000 kg holding force for wooden, metal, glass and PVC doors. Power is 12 or 24 V DC: 320 mA at 12 V, 160 mA at 24 V.
These figures set the power supply choice: the strike's current is added to that of the controller and reader. On a long cable run 24 V is the easier option, since half the current means a smaller voltage drop in the cable.
- SE-8LKNO-S, fail secure: the door stays locked without power.
- SE-8LKNC-S, fail safe: the door opens when power is removed.
- 304 stainless steel, mechanical test of 1 million cycles, CE certified.
- Operating range -10 to +55 °C.
Power for every device on the door is worked out during access control installation.
Specifications
| Certifications | CE |
|---|
| Lock behaviour on power loss | Fail secure (NO); Fail safe (NC) |
|---|---|
| Holding force | 1000 kg |
| Power supply | DC12 V or DC24 V |
|---|---|
| Current draw | 12 V/320 mA; 24 V/160 mA |
| Material | 304 Stainless Steel |
|---|---|
| Operating temperature | -10 °C – +55 °C (14-131F) |
| Operating humidity | 0 – 95% |
| Mechanical life | Mechanical test: 1,000,000 times |
| Door type | Wooden door/Metal door/Glass door/PVC door |
Used in solutions
FAQ
Why is door closer needed in Access Control System?
Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.
How to choose correct closer for door weight?
Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.
Can door closer integrate with fire alarm?
Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.
Need it installed?