Skip to content
SESAME

SESAME SE-8LNO/SE-8LNC electric strike

Model
9361

Electric strike in 304 stainless steel with 1000 kg holding force, for wooden, metal, glass and PVC doors.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Holding force
1000 kg
Power supply
DC12 V or DC24 V
Operating temperature
-10 °C – +55 °C (14-131F)
Door type
Wooden door/Metal door/Glass door/PVC door
All specifications

Description

The SESAME SE-8LNO/SE-8LNC is an electric strike in 304 stainless steel with 1000 kg holding force. Door types: wooden, metal, glass and PVC.

Two versions by behaviour on power loss: SE-8LNO is fail secure (the door stays locked), SE-8LNC is fail safe (the door opens).

  • Mechanical test: 1 million cycles.
  • 12 or 24 V DC; 320 mA at 12 V or 160 mA at 24 V.
  • Operating range -10 to +55 °C, humidity up to 95 %.
  • Adjustable distance to the mechanical lock's latch; CE certified.

Strike, mechanical lock and controller are matched to the specific door during access control installation.

Specifications

General
CertificationsCE
Access control
Lock behaviour on power lossFail secure (NO); Fail safe (NC)
Holding force1000 kg
Power
Power supplyDC12 V or DC24 V
Current draw12 V/320 mA; 24 V/160 mA
Physical and environment
Material304 Stainless Steel
Operating temperature-10 °C – +55 °C (14-131F)
Operating humidity0 – 95%
Mechanical lifeMechanical test: 1,000,000 times
Door typeWooden door/Metal door/Glass door/PVC door

FAQ

Why is door closer needed in Access Control System?

Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.

How to choose correct closer for door weight?

Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.

Can door closer integrate with fire alarm?

Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.

Need it installed?

LAGI will deliver, install and set up the equipment and provide warranty service afterwards.