SESAME SE-8NO/SE-8NC electric strike
- Model
- 9363
Electric strike with 1000 kg holding force in two versions: with the SE-8NO the door stays locked without power, with the SE-8NC the door opens.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Holding force
- 1000 kg
- Power supply
- DC12 V or DC24 V
- Operating temperature
- -10 °C – +55 °C (14-131F)
- Door type
- Wooden door/Metal door/Glass door/PVC door
Description
The SESAME SE-8NO/SE-8NC is an electric strike with 1000 kg holding force, made in two versions. The strike goes into the door frame in place of the mechanical lock's strike plate, and the door opens on a signal from the access controller.
- SE-8NO (fail secure): the door stays locked without power and opens when power is applied. For doors that must stay locked during a power cut.
- SE-8NC (fail safe): the door opens when power is removed. Usually fitted on doors along escape routes.
Common to both versions:
- 12 or 24 V DC; 320 mA at 12 V, 160 mA at 24 V.
- 304 stainless steel, mechanical test of 1 million cycles.
- Wooden, metal, glass and PVC doors; operating range -10 to +55 °C.
The version is chosen to suit the door and fire safety requirements during access control installation.
Specifications
| Certifications | CE |
|---|
| Lock behaviour on power loss | Fail secure (NO); Fail safe (NC) |
|---|---|
| Holding force | 1000 kg |
| Power supply | DC12 V or DC24 V |
|---|---|
| Current draw | 12 V/320 mA; 24 V/160 mA |
| Material | 304 Stainless Steel |
|---|---|
| Operating temperature | -10 °C – +55 °C (14-131F) |
| Operating humidity | 0 – 95% |
| Mechanical life | Mechanical test: 1,000,000 times |
| Door type | Wooden door/Metal door/Glass door/PVC door |
Used in solutions
FAQ
Why is door closer needed in Access Control System?
Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.
How to choose correct closer for door weight?
Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.
Can door closer integrate with fire alarm?
Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.