SESAME magnetic shear lock, 1200 kg
- Model
- 9340
Magnetic shear lock with 1200 kg holding force: two fixed pins entering holes in the armature plate add to the magnetic pull.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Holding force
- 2600Lbs (1200 kg)
- Power supply
- DC 12 V (24 V need order)
- Dimensions
- 182L × 30 W × 25D (mm)
Description
The SESAME SM-2400SL is a magnetic shear lock with 1200 kg holding force. Under power the armature plate is drawn to the electromagnet and two fixed pins enter holes in the plate. The door is held by both the magnetic pull and the pins' resistance to shear, which is where the high force comes from.
- Locking delay: 0, 5, 10 or 15 s.
- Status light: red for locked, green for open.
- Door sensor (NO/COM) and lock status sensor (NC/NO/COM) outputs, 0.1 A at 30 V DC.
- 12 V DC power (24 V to order), 850 mA, 400 mA while holding.
- Lock 182 × 30 × 25 mm, armature plate 182 × 30 × 23.6 mm, 1.2 kg.
The gap between lock and plate must not exceed 3 mm, so both are marked out and aligned with care during access control installation.
Specifications
| Door sensor | NO/COM (0.1 A@30VDC) |
|---|---|
| Lock delay | 0/5/10/15sec |
| Holding force | 2600Lbs (1200 kg) |
| Lock status sensor | NC/NO/COM (0.1 A@30VDC) |
| Indicators | Red shows locked; Green shows unlocked |
|---|
| Power supply | DC 12 V (24 V need order) |
|---|---|
| Current draw | 850 mA |
| Holding current | 400 mA |
| Dimensions | 182L × 30 W × 25D (mm) |
|---|---|
| Net weight | 1.2 kg |
| Maximum armature gap | 3 mm |
| Strike plate size | 182L × 30 W × 23.6D (mm) |
Used in solutions
FAQ
Why is door closer needed in Access Control System?
Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.
How to choose correct closer for door weight?
Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.
Can door closer integrate with fire alarm?
Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.