Skip to content
SESAME

SESAME SM-280D-T/SM-280D-ST double magnetic lock

Model
9378

Double magnetic lock with 280 kg holding force and an adjustable lock delay of 0, 3, 6 or 9 s, powered at 12 or 24 V DC.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Holding force
280 kg
Power supply
12 V DC / 24 V DC
Dimensions
500 × 42 mm (lock); 180 × 38 mm (each armature plate)
All specifications

Description

The SESAME SM-280D-T is a double magnetic lock with a lock delay, for double doors in wood, glass and metal. A 500 × 42 mm body and two 180 × 38 mm armature plates, one for each leaf.

Holding force under power: 280 kg. The door opens when power is cut by the access controller or the exit button.

  • Adjustable lock delay: 0, 3, 6 or 9 s.
  • 12 V DC or 24 V DC power.
  • Status light: red for standby, green for released.
  • Anti-residual magnetism and a varistor (MOV) against reverse current at switch-off.
  • Anodised aluminium alloy body with no wearing mechanical parts.

Whether a delay is needed, and how long, we decide with you during access control installation.

Specifications

Access control
Lock delay0,3,6,9 sec. Adjustment
Holding force280 kg
Hardware
IndicatorsRed: stand by; Green: unlocked
Power
Power supply12 V DC / 24 V DC
Physical and environment
Dimensions500 × 42 mm (lock); 180 × 38 mm (each armature plate)

FAQ

Why is door closer needed in Access Control System?

Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.

How to choose correct closer for door weight?

Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.

Can door closer integrate with fire alarm?

Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.

Need it installed?

LAGI will deliver, install and set up the equipment and provide warranty service afterwards.