ZKTeco EB101 exit button
- Model
- 9526
Mechanical exit button in a stainless steel housing with IK10 impact protection and a blue backlight.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Dimensions
- 115mm * 40mm * 28.6mm (L*W*H)
- Operating temperature
- -20°C ~ +50°C
Description
The ZKTeco EB101 is a mechanical exit button: a press from inside opens a door with an electric lock, no card or code needed.
- 1.7 mm stainless steel plate, IK10 impact rating.
- Blue LED backlight with a rated life of about 40000 h.
- 12–24 V DC circuits, contacts rated at 5 A.
- 115 × 40 × 28.6 mm, operating range -20 to 50 °C.
Wiring goes to the access controller or straight into the lock circuit; the scheme is chosen during access control installation.
Specifications
| Exit button operation | Self-replication |
|---|
| Lamp type | LED |
|---|---|
| Lamp life | 40000h (reference value) |
| Lamp colour | Blue |
| Switching voltage | DC 12 ~ 24V |
|---|---|
| Rated current | 5A |
| Voltage conversion | Built-in step-down converters |
| Operating humidity | 10% - 90% |
|---|---|
| Storage temperature | -20°C ~ +65°C |
| Dimensions | 115mm * 40mm * 28.6mm (L*W*H) |
| Impact protection (IK) | IK10 |
| Material | 1.7mm stainless steel plate |
| Pin material | Copper plated |
| Head shape | Plane, power supply standard |
| Operating temperature | -20°C ~ +50°C |
Used in solutions
FAQ
What's the difference between NO and NC contacts?
NO (Normally Open) – in normal state contact is open (no current flows). When you press button, contact closes and current flows → controller receives signal and door opens. This is most common type. NC (Normally Closed) – in normal state contact is closed (current flows). When you press button, contact opens and current stops → controller receives signal. Used in special cases. Most controllers require NO contact.
What type of exit button suits my facility?
Depends on facility type and environment. Offices/indoor doors – mechanical plastic button (cheap, sufficient). Public places/outdoor doors – vandal-resistant metal button (durable). Hospitals/hotels – contactless touchless button (hygienic, No Touch). Dark corridors/emergency exits – illuminated LED button (visible at night). Outdoor conditions – IP65/IP68 weatherproof button (rain, snow).
Can exit button be used on emergency exit?
Yes, but must comply with emergency exit requirements. On emergency exit, exit button must be: 1) visible and easily accessible (maximum 1.5m height), 2) illuminated LED with "PUSH TO EXIT" or "EMERGENCY EXIT" text, 3) connected to fail-safe lock (opens when power cuts), 4) additionally recommended Break Glass Emergency Release as backup solution. This is mandatory for fire safety standards compliance.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.