ZKTeco EB104 exit button
- Model
- 9523
Mechanical exit button on a square 86 × 86 mm aluminium plate: 4 mm thick metal and IK10 impact protection.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Dimensions
- 86mm * 86mm * 38.5mm (L*W*H)
- Operating temperature
- -20°C ~ +50°C
Description
The ZKTeco EB104 is a mechanical exit button on a square 86 × 86 mm aluminium plate. A press from inside opens a door with an electric lock; leaving needs no card or code.
- 4 mm aluminium, vertical brushed finish, black lettering.
- IK10 impact rating.
- 12–24 V DC circuits, contacts rated at 5 A, built-in step-down converter.
- 86 × 86 × 38.5 mm overall.
- Operating range -20 to 50 °C, storage -20 to 65 °C.
The button goes to the access controller or into the lock circuit during access control installation.
Specifications
| Exit button operation | Self-replication |
|---|
| Switching voltage | DC 12 ~ 24V |
|---|---|
| Rated current | 5A |
| Voltage conversion | Built-in step-down converters |
| Storage temperature | -20°C ~ +65°C |
|---|---|
| Dimensions | 86mm * 86mm * 38.5mm (L*W*H) |
| Operating humidity | 10% - 90% |
| Impact protection (IK) | IK10 |
| Material | 4mm aluminum plate |
| Finish | Printed black characters + vertical drawing |
| Operating temperature | -20°C ~ +50°C |
Used in solutions
FAQ
What's the difference between NO and NC contacts?
NO (Normally Open) – in normal state contact is open (no current flows). When you press button, contact closes and current flows → controller receives signal and door opens. This is most common type. NC (Normally Closed) – in normal state contact is closed (current flows). When you press button, contact opens and current stops → controller receives signal. Used in special cases. Most controllers require NO contact.
What type of exit button suits my facility?
Depends on facility type and environment. Offices/indoor doors – mechanical plastic button (cheap, sufficient). Public places/outdoor doors – vandal-resistant metal button (durable). Hospitals/hotels – contactless touchless button (hygienic, No Touch). Dark corridors/emergency exits – illuminated LED button (visible at night). Outdoor conditions – IP65/IP68 weatherproof button (rain, snow).
Can exit button be used on emergency exit?
Yes, but must comply with emergency exit requirements. On emergency exit, exit button must be: 1) visible and easily accessible (maximum 1.5m height), 2) illuminated LED with "PUSH TO EXIT" or "EMERGENCY EXIT" text, 3) connected to fail-safe lock (opens when power cuts), 4) additionally recommended Break Glass Emergency Release as backup solution. This is mandatory for fire safety standards compliance.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.