TIRAS

SPR Tiras Ex conventional manual call point

Model
6542

SPR Tiras Ex conventional manual call point for explosive atmospheres: a manual “Fire” signal, 8–28 V supply.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Power supply
8-28 V
Operating temperature
-10 °C – +55 °C
Dimensions
93 × 90 × 43 mm
All specifications

Description

The SPR Tiras Ex is a conventional manual call point for explosive atmospheres. It sends a manual “Fire” signal in a conventional fire alarm system.

  • Intrinsically safe version for hazardous areas, used with the MBI-2 barrier module.
  • Supply 8–28 V; 0.1 mA in standby, up to 22 mA when activated.
  • Operating temperature -10 °C – +55 °C; housing 93 × 90 × 43 mm, IP30.

LAGI plans where call points go as part of fire alarm installation.

Specifications

Power
Power supply8-28 V
Current drawStandby current consumption: 0.1 mA; max. in fire alarm mode: 22 mA
Physical and environment
Operating temperature-10 °C – +55 °C
Ingress protection (IP)IP30
Dimensions93 × 90 × 43 mm

FAQ

What's the difference between addressable and conventional alarm buttons?

Addressable buttons – each button has unique ID number, fire panel knows exactly which button activated and where located (e.g. "3rd floor, east staircase"), 2-wire connection, more expensive, ideal for large buildings. Conventional buttons – buttons grouped into zones (e.g. "Zone 3 - 3rd floor"), panel knows only zone, not precise location, 4-wire connection, cheaper, ideal for small buildings. Recommendation: addressable – hotels, hospitals, shopping centers. Conventional – offices, shops, factories.

How often should fire alarm manual call points be tested?

Fire alarm manual call points must be tested regularly to ensure safety. Recommendations: 1) weekly visual inspection – ensure button not damaged, glass intact, LED indicator working. 2) monthly functional test – use test key (for resettable buttons) or press button (for single-use buttons) and ensure siren activated. 3) annual professional inspection – full check by certified technician. This is mandatory for fire safety standards compliance.

Where should fire alarm manual call points be installed?

Correct placement of fire alarm manual call points is critical for effective evacuation. Recommendations: 1) at evacuation exits – at all emergency exits, stairs, in corridors. 2) height – 1.2-1.5m from floor (easily accessible for everyone including children and disabled). 3) visibility – button must be visible and easily noticeable (red color, "FIRE" text). 4) distance – maximum 30-45m distance between buttons (person must reach button in 30 seconds). 5) protection – avoid locations where button can be damaged (high traffic, transport).

Need it installed?

LAGI will deliver, install and set up the equipment and provide warranty service afterwards.