SPR Tiras Ex conventional manual call point
- Model
- 6542
SPR Tiras Ex conventional manual call point for explosive atmospheres: a manual “Fire” signal, 8–28 V supply.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Power supply
- 8-28 V
- Operating temperature
- -10 °C – +55 °C
- Dimensions
- 93 × 90 × 43 mm
Description
The SPR Tiras Ex is a conventional manual call point for explosive atmospheres. It sends a manual “Fire” signal in a conventional fire alarm system.
- Intrinsically safe version for hazardous areas, used with the MBI-2 barrier module.
- Supply 8–28 V; 0.1 mA in standby, up to 22 mA when activated.
- Operating temperature -10 °C – +55 °C; housing 93 × 90 × 43 mm, IP30.
LAGI plans where call points go as part of fire alarm installation.
Specifications
| Power supply | 8-28 V |
|---|---|
| Current draw | Standby current consumption: 0.1 mA; max. in fire alarm mode: 22 mA |
| Operating temperature | -10 °C – +55 °C |
|---|---|
| Ingress protection (IP) | IP30 |
| Dimensions | 93 × 90 × 43 mm |
Used in solutions
- Security systems for apartment buildings See the solution
- Security systems for hotels and guesthouses See the solution
- Security systems for shops See the solution
- Security systems for offices See the solution
- Security systems for schools and kindergartens See the solution
- Security systems for warehouses and logistics centres See the solution
FAQ
What's the difference between addressable and conventional alarm buttons?
Addressable buttons – each button has unique ID number, fire panel knows exactly which button activated and where located (e.g. "3rd floor, east staircase"), 2-wire connection, more expensive, ideal for large buildings. Conventional buttons – buttons grouped into zones (e.g. "Zone 3 - 3rd floor"), panel knows only zone, not precise location, 4-wire connection, cheaper, ideal for small buildings. Recommendation: addressable – hotels, hospitals, shopping centers. Conventional – offices, shops, factories.
How often should fire alarm manual call points be tested?
Fire alarm manual call points must be tested regularly to ensure safety. Recommendations: 1) weekly visual inspection – ensure button not damaged, glass intact, LED indicator working. 2) monthly functional test – use test key (for resettable buttons) or press button (for single-use buttons) and ensure siren activated. 3) annual professional inspection – full check by certified technician. This is mandatory for fire safety standards compliance.
Where should fire alarm manual call points be installed?
Correct placement of fire alarm manual call points is critical for effective evacuation. Recommendations: 1) at evacuation exits – at all emergency exits, stairs, in corridors. 2) height – 1.2-1.5m from floor (easily accessible for everyone including children and disabled). 3) visibility – button must be visible and easily noticeable (red color, "FIRE" text). 4) distance – maximum 30-45m distance between buttons (person must reach button in 30 seconds). 5) protection – avoid locations where button can be damaged (high traffic, transport).