DETECTO HT10 Ex conventional heat detector
- Model
- 6543
DETECTO HT10 Ex conventional microprocessor heat detector for hazardous areas, with DETECTO PLUS mode, in a white or black housing.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Power supply
- 10-30 V
- Dimensions
- 110 × 48 mm
Description
The DETECTO HT10 Ex is a conventional microprocessor heat detector for hazardous areas for Tiras PRIME and other conventional fire alarm panels.
- Intrinsically safe design for boiler rooms, production sites, mills, grain elevators and stores of explosive substances; used with the MBI-2 barrier module.
- Triggers when the temperature passes the class A2 or B threshold; suitable for kitchens and boiler rooms.
- DETECTO PLUS mode with Tiras PRIME II panels: the panel gets a signal when the chamber is dirty or the sensor fails, and no end-of-line resistor is needed.
- Indication of standby, fault and fire; a remote indicator can be connected.
- Supply 10–30 V; 0.1 mA in standby, 16–31 mA in alarm; housing 110 × 48 mm, IP30.
LAGI selects and positions detectors as part of fire alarm installation.
Specifications
| Temperature class | A2 or B |
|---|
| Power supply | 10-30 V |
|---|---|
| Current draw | Standby current consumption: 0.1 mA; in fire alarm mode at 13.7 V: 16 mA; at 30 V: 31 mA |
| Ingress protection (IP) | IP30 |
|---|---|
| Dimensions | 110 × 48 mm |
| Net weight | 120 g |
| Color | White, Black |
Used in solutions
- Security systems for apartment buildings See the solution
- Security systems for hotels and guesthouses See the solution
- Security systems for shops See the solution
- Security systems for offices See the solution
- Security systems for schools and kindergartens See the solution
- Security systems for warehouses and logistics centres See the solution
FAQ
What's the difference between heat and smoke detectors?
Smoke detectors – detect smoke particles in air, faster response (several minutes earlier), ideal for living rooms, bedrooms, corridors, but cause false alarms in kitchen (cooking), bathroom (steam), garage (dust). Heat detectors – detect temperature rise, don't react to smoke/steam/dust, slower response (several minutes later), ideal for kitchens, bathrooms, garages, warehouses. Recommendation: smoke detectors – bedrooms, corridors. Heat detectors – kitchen, bathroom, garage. Combination – best protection.
What is Rate-of-Rise (ROR) function in heat detector?
Rate-of-Rise (ROR) is function that detects rapid temperature rise over time. How it works: detector measures temperature every second and calculates rise rate. If temperature rises more than 8-10°C/min, detector triggers even if temperature hasn't reached fixed threshold (e.g. 57°C). This provides faster response than fixed temperature detectors. Example: room temperature 20°C → fire starts → temperature rises 20°C → 35°C → 50°C (in 30 seconds) → ROR detector triggers at 50°C, fixed detector triggers at 57°C (10 seconds later).
Where should I use heat detectors instead of smoke detectors?
Heat detectors are recommended for locations where smoke detectors cause false alarms: 1) kitchen – cooking produces smoke/steam, heat detector doesn't react. 2) bathroom – hot water steam causes false alarm in smoke detector. 3) garage – dust, car exhaust, heat detector more reliable. 4) warehouse – dusty environment, heat detector doesn't react to dust. 5) attic/basement – high humidity, temperature fluctuations. 6) industrial facilities – welding, cutting, dusty processes. Important: heat detectors should not be used in bedrooms – use smoke detectors.