DETECTO SMK10 Ex conventional smoke detector

Model
6544

DETECTO SMK10 Ex conventional microprocessor smoke detector for hazardous areas, with DETECTO PLUS mode, in a white or black housing.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Power supply
10-30 V
Dimensions
110 × 48 mm
All specifications

Description

The DETECTO SMK10 Ex is a conventional microprocessor smoke detector for hazardous areas for Tiras PRIME and other conventional fire alarm panels.

  • Intrinsically safe design for boiler rooms, production sites, mills, grain elevators and stores of explosive substances; used with the MBI-2 barrier module.
  • Dust-resistant smoke chamber and compensation for temperature, dust and ageing, so maintenance is needed several times less often.
  • DETECTO PLUS mode with Tiras PRIME II panels: the panel gets a signal when the chamber is dirty or the sensor fails, and no end-of-line resistor is needed.
  • Indication of standby, fault and fire; a remote indicator can be connected.
  • Supply 10–30 V; 0.11 mA in standby, 16–31 mA in alarm; housing 110 × 48 mm, IP30.

LAGI selects and positions detectors as part of fire alarm installation.

Specifications

Power
Power supply10-30 V
Current drawStandby current consumption: 0.11 mA; in fire alarm mode at 13.7 V: 16 mA; at 30 V: 31 mA
Physical and environment
Ingress protection (IP)IP30
Dimensions110 × 48 mm
Net weight120 g
ColorWhite, Black

FAQ

What's the difference between optical and ionization smoke detectors?

Optical (photoelectric) detectors – use LED light and photodiode, detect smoke particles by light scattering, ideal for slow smoldering fires (furniture, fabric), fewer false alarms, safe (no radioactive material), recommended for residential homes. Ionization detectors – use radioactive source (Americium-241), detect invisible smoke particles, ideal for fast flaming fires (paper, gasoline), faster response, but more false alarms. Recommendation: optical – residential homes, offices. Ionization – kitchens, warehouses. Dual sensor – best option (both fire types).

Where should I install smoke detectors?

Correct smoke detector placement is critical for effective protection. Recommendations: 1) in all bedrooms – detector must be in all bedrooms and in corridor near bedrooms. 2) on all floors – minimum one detector per floor including basement and attic. 3) on ceiling – detector must be installed on ceiling or on wall 10-30cm from ceiling (smoke rises up). 4) avoid – kitchen (false alarms when cooking), bathroom (steam), windows/doors (air flow). 5) distance – maximum 10-15m distance between detectors. 6) testing – monthly press test button and ensure siren works.

How often should I replace smoke detector battery?

Smoke detector battery life depends on type. Standard 9V battery – 6-12 months, detector beeps when battery weakens (one beep every 30-60 seconds), replace immediately. 10-year lithium battery – 10 years, built into detector, no replacement needed, after 10 years replace entire detector. AC power (220V) + backup battery – backup battery 1-2 years. Recommendation: replace battery twice per year (when changing clocks), replace entire detector after 10 years (sensor ages and loses accuracy).