There are no products to list in this category.
ContinueFire Automation — Control Modules in Tbilisi
Fire Automation (Fire Control Modules) are intelligent systems that automatically manage building infrastructure during fire and perform critical operations such as HVAC shutdown (prevent smoke spread), elevator recall to first floor (evacuation safety), fire door closure (smoke containment), water sprinkler activation (automatic suppression), gas/power shutoff (prevent additional hazards) in Tbilisi and throughout Georgia. These modules integrate with fire alarm panel and provide coordinated response during fire, which is essential for large buildings, hotels, hospitals, shopping centers, offices, and any type of commercial facilities. LAGI offers full range of fire automation modules: fire relay modules (NO/NC contacts, 230V/16A, HVAC/elevator control), Input/Output modules (monitoring and control, 8-16 I/O), zone expansion modules (additional zones), electromagnetic door holders (Fire Door Holders, 24V DC, automatic release), sprinkler control modules (water flow monitoring, valve control), HVAC shutdown modules (ventilation cutoff, smoke spread prevention), elevator recall modules (automatic return to first floor). All modules comply with European standards EN 54 and EN 12101.
Main Components of Fire Automation
- Fire relay modules — NO/NC contacts, 230V/16A load, HVAC/elevator/lighting control, automatic activation during fire, resettable.
- Input/Output modules — 8-16 I/O ports, monitoring (door status, water flow) and control (valves, sirens), addressable/conventional versions.
- Electromagnetic door holders — Fire Door Holders, 24V DC, automatic release during fire, automatic door closure, ideal for fire doors, smoke barriers.
- Sprinkler control modules — water flow monitoring (Flow Switch), valve control, pressure sensors, automatic activation, fire panel integration.
- HVAC shutdown modules — automatic cutoff during fire, smoke spread prevention, relay output 230V/16A, ideal for large buildings.
- Elevator recall modules — automatic return to first floor, door opening, elevator shutdown, evacuation safety, EN 81-73 standard.
FAQ — Frequently Asked Questions
HVAC system during fire can become channel for smoke and fire spread throughout building. How it works: in normal mode HVAC circulates air in all rooms, but during fire this means smoke and hot air rapidly spread to clean zones. Automatic shutdown benefits: 1) smoke containment — smoke stays in fire zone and doesn't spread to other floors/rooms. 2) evacuation time — people have more time for safe evacuation. 3) fire slowdown — oxygen supply limitation slows fire spread. 4) firefighter assistance — firefighters can localize fire easier. Fire automation module automatically shuts down HVAC when fire panel detects fire.
Elevator Recall is life-saving safety function that prevents people from being trapped in elevator during fire. How it works: 1) fire detection — fire panel detects fire and sends signal to elevator control module. 2) automatic return — elevator ignores all calls and automatically returns to first floor (or designated evacuation floor). 3) door opening — elevator opens doors and releases all passengers. 4) elevator shutdown — elevator stays on first floor with open doors and no longer responds to calls. 5) firefighter mode — elevator can only be used by firefighters with special key. This ensures people won't be trapped in elevator in smoke-filled shaft.
Fire Door Holder (Electromagnetic Door Holder) is electromagnetic device that holds fire door in open position during normal time and automatically releases it during fire. How it works: 1) normal mode — electromagnet (24V DC) holds door in open position, people pass freely. 2) fire detection — fire panel detects fire and cuts power supply to holder. 3) automatic release — electromagnet turns off and door automatically closes (thanks to door closer). 4) smoke barrier — closed door blocks smoke and fire spread to other zones. Benefit: during normal time door is open (comfort), during fire door automatically closes (safety). Ideal for corridors, stairs, evacuation routes.