SESAME SE-3NC electric strike
- Model
- 9371
Fail-safe electric strike with 500 kg holding force: the door opens when power is cut. 12 V DC, 24 V DC to order.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Power supply
- 12VDC (24VDC need order)
- Dimensions
- 10-12MM (KEEP)
Description
The SESAME SE-3NC is a fail-safe (NC) electric strike: when power is cut, the latch of the mechanical lock is released and the door opens. Fitted in the door frame opposite the latch.
- 12 V DC power, 24 V DC to order.
- Current: 200 mA at 12 V, 100 mA at 24 V.
- 500 kg holding force.
- Tested to 100000 cycles, CE marked.
- Face plate 160 × 25 × 31 mm.
The 24 V version is chosen when the access control system runs on 24 V; this is decided during access control installation.
Specifications
| Certifications | CE |
|---|
| Lock behaviour on power loss | FAIL-SAFE (NC) |
|---|
| Power supply | 12VDC (24VDC need order) |
|---|---|
| Current draw | 12 V/200 mA; 24 V/100 mA |
| Dimensions | 10-12MM (KEEP) |
|---|---|
| Lock panel size | 160L × 25 W × 31H (MM) |
Used in solutions
FAQ
Why is door closer needed in Access Control System?
Door closer is essential in Access Control System for several reasons: 1) correct electric lock operation – lock closes only if door is fully closed, closer ensures this, 2) security – door always closes and locks, doesn't stay open, 3) energy efficiency – closed door maintains temperature, 4) comfort – requires no manual closing. Without closer, electric lock won't work correctly.
How to choose correct closer for door weight?
Closers are classified by EN 1154 standard by force (EN 1-7): EN 1-2 – 20-40kg (light doors, internal offices), EN 3-4 – 40-80kg (standard doors, most common), EN 5-6 – 80-120kg (heavy doors, entrances), EN 7 – 120-200kg (very heavy doors, fire-rated). Measure door weight and select corresponding EN class. Wrong choice leads to rapid wear or insufficient force.
Can door closer integrate with fire alarm?
Yes, electromagnetic Hold-Open closers integrate with fire alarm – door is fixed in open position by electromagnet, and when fire alarm activates, electromagnet releases and door automatically closes (fire-rated doors, evacuation routes). This is mandatory for EN 1154 and fire safety standards compliance. Integration with access control (remote release) is also possible.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.