ZKTeco TLEB102 no-touch exit button
- Model
- 9527
No-touch exit button in a rectangular 115 × 70 mm SUS304 stainless steel housing, triggered by a hand 2–10 cm from the panel.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Dimensions
- 115mm * 70mm * 38mm (L*W*H)
- Operating temperature
- -20°C ~ +50°C
Description
The ZKTeco TLEB102 is a no-touch exit button with an IR sensor in a rectangular 115 × 70 × 38 mm housing of SUS304 stainless steel. A wave of the hand in front of the panel opens the door, with no need to touch the button.
- Trigger distance 2–10 cm.
- Switching: 9–16 V DC, rated current 2 A.
- Operating range -20 to +50 °C at 10–90 % humidity; storage -20 to +65 °C.
The mounting spot and the controller connection are decided during access control installation.
Specifications
| IR sensor range | 2 - 10cm |
|---|
| Switching voltage | DC 9 ~ 16V |
|---|---|
| Rated current | 2A |
| Operating humidity | 10% - 90% |
|---|---|
| Storage temperature | -20°C ~ +65°C |
| Dimensions | 115mm * 70mm * 38mm (L*W*H) |
| Material | SUS304 stainless steel |
| Operating temperature | -20°C ~ +50°C |
Used in solutions
FAQ
What's the difference between NO and NC contacts?
NO (Normally Open) – in normal state contact is open (no current flows). When you press button, contact closes and current flows → controller receives signal and door opens. This is most common type. NC (Normally Closed) – in normal state contact is closed (current flows). When you press button, contact opens and current stops → controller receives signal. Used in special cases. Most controllers require NO contact.
What type of exit button suits my facility?
Depends on facility type and environment. Offices/indoor doors – mechanical plastic button (cheap, sufficient). Public places/outdoor doors – vandal-resistant metal button (durable). Hospitals/hotels – contactless touchless button (hygienic, No Touch). Dark corridors/emergency exits – illuminated LED button (visible at night). Outdoor conditions – IP65/IP68 weatherproof button (rain, snow).
Can exit button be used on emergency exit?
Yes, but must comply with emergency exit requirements. On emergency exit, exit button must be: 1) visible and easily accessible (maximum 1.5m height), 2) illuminated LED with "PUSH TO EXIT" or "EMERGENCY EXIT" text, 3) connected to fail-safe lock (opens when power cuts), 4) additionally recommended Break Glass Emergency Release as backup solution. This is mandatory for fire safety standards compliance.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.