Skip to content
FYB

FYB FY-70B – FY-800B PA power amplifier

Model
FYB-549764

Single-channel power amplifier for a 19" rack: 70 V, 100 V or 4–16 Ω output, balanced and unbalanced inputs with cascade outputs, 70–800 W.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Power supply
AC220 V/50 Hz-60 Hz
Rated power output
70 W/130/180/260/300/360/500/650/800 W
Frequency response
50 Hz~16KHz (+1 dB, -3 dB)
Dimensions
482 (width) * 380 (depth) * 88 (height) mm excluding machine feet
Operating temperature
5 °C~40 °C
All specifications

Description

FYB FY-70B – FY-800B: single-channel PA power amplifiers rated at 70–800 W for a 19" rack. The usual place is the equipment room of a PA zone; the line runs from the amplifier to speakers in halls, corridors and outdoor areas.

Connections

  • LINE input on a 6.35 mm jack (775 mV, 10 kΩ, unbalanced) with a cascade output to the next amplifier.
  • Balanced XLR input with an XLR cascade output.
  • Output to a 70 V or 100 V line or to 4–16 Ω speakers, so ordinary loudspeakers can be used too.
  • 220 V mains through a Phoenix connector, T3 A fuse.

Protection

  • Output cut-off on DC at the output and on short circuit, with automatic recovery after a short.
  • Output cut-off if the transformer goes above 105 °C, amplifier shutdown above 85 °C inside the case.
  • Soft start, with no current surge at switch-on.
  • Limiter: clipping caused by a mains voltage drop, heavy load, an oversized input signal or heat is corrected automatically.

Forced-air cooling from front to back, with fan speed following the temperature. Indicators for signal level, distortion, protection and overheating. 50 Hz – 16 kHz response, signal-to-noise ratio above 90 dB. 482 × 380 × 88 mm, operating range 5–40 °C. Power is chosen to match the line load when audio and public address systems are designed.

Specifications

Hardware
Indicatorsit can display the output signal strength, distortion, protection and over-temperature status
Power
Power supplyAC220 V/50 Hz-60 Hz
Electrical protectionAC FUSE*T3 A × 1
Power cord(3 × 0.75 mm)*1.5M (standard)
Power connectorThree-position phoenix tail plug interface
Audio
Rated power output70 W/130/180/260/300/360/500/650/800 W
Outputs70 V, 100 V & 4~16Ω
Frequency response50 Hz~16KHz (+1 dB, -3 dB)
Signal-to-noise ratio>90 dB
Total harmonic distortion0.5% at 1KHz, 1/3 output power
Input sensitivity775mV/10KΩ, unbalanced 6.35 interface
Output level775mV/470Ω, unbalanced 6.35 interface
Physical and environment
Dimensions482 (width) * 380 (depth) * 88 (height) mm excluding machine feet
Net weight7.5 kg
Mountingrack installation
Operating temperature5 °C~40 °C
Operating humidity20% to 80% relative humidity, no condensation

FAQ

What's the difference between a power amplifier and a mixer amplifier?

Power amplifier – only amplifier (no mixer), 1-2 inputs (line level, balanced XLR), no volume control on inputs, no priority function, high power (350W-2000W), 40-200+ speakers, requires separate pre-amplifier or mixer for microphones and volume control, ideal for large facilities (shopping malls, airports, stadiums), professional systems, rack mount design (19" rack). Mixer amplifier – integrated all-in-one (mixer + amplifier), 4-12 inputs (microphones, line inputs), volume/bass/treble control on each input, priority function, medium power (60W-650W), 6-80 speakers, doesn't require separate mixer, ideal for small-medium facilities (stores, schools, restaurants), all-in-one solution. Recommendation: power amplifier – large facilities (>80 speakers), professional systems, separate mixer. Mixer – small-medium facilities (<80 speakers), all-in-one solution.

What is bridge mode and parallel mode and when to use them?

Bridge mode and Parallel mode are special configurations allowing you to change amplifier operation mode. Bridge mode (bridged mono) – combines 2 channels into one powerful channel, doubled power (example: 2× 500W → 1× 1000W), used when very high power needed for one zone, ideal for large spaces (100-200 speakers in one zone), connection: + channel 1, - channel 2. Parallel mode – combines 2 channels in parallel, same power but doubled speaker quantity (example: 2× 500W → 2× 500W but each channel can power 2x more speakers), used when more speakers needed than one channel can handle, ideal for multi-zone systems (2 zones with same power), connection: both channels in parallel. When to use: 1) Bridge mode – when very high power needed for one zone (>100 speakers), large spaces, one zone. 2) Parallel mode – when more speakers needed than one channel can handle, multi-zone systems, 2 zones with same power. 3) Normal mode (stereo) – when 2 independent zones with different power needed, multi-zone systems. Recommendation: most common mode is Normal mode (stereo), Bridge mode used rarely (for very large spaces).

How do I connect a power amplifier?

Connecting a power amplifier requires a pre-amplifier or mixer. Steps: 1) Pre-amplifier/Mixer connection – connect pre-amplifier or mixer output (line output, balanced XLR or RCA) to power amplifier input (input, balanced XLR), use balanced XLR cable (better sound quality, less noise). 2) speaker connection – connect speaker cable (2-core, 2.5mm² or 4mm² for high power) from amplifier 100V/70V outputs to speakers (parallel connection, all speakers in parallel). 3) speaker configuration – on each 100V speaker select power (tap selector: 3W/6W/10W/20W), ensure total power doesn't exceed amplifier power on each channel. 4) Gain adjustment – adjust gain (input sensitivity) on each channel (typically 0dB to +20dB), start from 0dB and increase if needed. 5) testing – turn on system, verify all speakers work, ensure no distortion, check protection LEDs (shouldn't be lit). 6) Rack mount – install amplifier in 19" rack (2U-3U space), leave 1U space above and below for ventilation. Recommendation: always use balanced XLR cables from pre-amplifier to amplifier (better sound quality, less noise).

Need it installed?

LAGI will deliver, install and set up the equipment and provide warranty service afterwards.