FYB FY-8800C audio matrix with FM tuner and MP3 player

Model
FY-8800C
SKU
FYB-172124

Central unit of a PA system: audio matrix, MP3 player, FM tuner, broadcasts on a weekly schedule and a link to the fire alarm.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Frequency response
20 Hz-20KHz±3 dB
Zones
8 partition outputs, with a total maximum capacity of 3200 W
All specifications

Description

The FYB FY-8800C is an audio matrix and the central unit of a PA system: music sources, broadcast scheduling, zone switching, amplifier power and the fire alarm link in one case. Typical sites are campuses, factories, parks, squares and residential areas.

What is inside

  • MP3 player and 88–108 MHz FM tuner; 6 audio sources plus a separate fire message input.
  • 2 GB of built-in memory and an SD card, with a computer connection for loading music; MP3, WMA, AAC, WAV, APE and FLAC.
  • 4 general schedules on a weekly cycle and 6 special ones for set dates, up to 256 events each; RTC clock accurate to the second.
  • 16 fire alarm inputs (contact closure).
  • 4 programmable amplifier power outputs and an expansion output; 220 V mains outlets up to 1600 W.
  • Recording from a microphone, the line input and the radio; schedules edited on a computer.

4.3" colour TFT screen, menus in English or Chinese. 500 mV line output, 20 Hz – 20 kHz ±3 dB, signal-to-noise ratio of 85 dB or more, 5 kg. The matrix and zones are set up during commissioning of audio and public address systems.

Specifications

Access control
Power outputAC220 V/50 Hz (MAX1600 W)
Hardware
Memorybuilt-in 2G memory or external SD card
Audio
OutputsLINE 500mV Unbalanced
Frequency response20 Hz-20KHz±3 dB
Signal-to-noise ratio≥85 dB
Total harmonic distortion<0.1% (1KHz)
Radio tunerFM 88-108 MHz
Audio formatsMP3, WMA, AAC, WAV, APE, FLAC
Input sensitivityMIC 5mV LINE 500mV
Zones8 partition outputs, with a total maximum capacity of 3200 W
Physical and environment
Net weight5Kg
Gross weight6Kg

FAQ

What is 100V constant voltage system and why is it needed?

100V constant voltage system is special audio technology using high voltage (100V) and low current for signal transmission. This allows: 1) connect dozens of speakers to one amplifier (50-100+ speakers), 2) use thin cables (0.75mm²-1.5mm²) over long distances (300-1000m), 3) minimal signal loss, 4) individual power adjustment of each speaker via transformer. Ideal for large facilities.

How many speakers can be connected to one amplifier?

Depends on amplifier power and speaker power. Formula: quantity = amplifier power ÷ speaker power. Example: 240W amplifier + 6W speakers = 40 speakers (240÷6=40). 500W amplifier + 10W speakers = 50 speakers. Always leave 20% reserve and consider zone distribution.

Can PA system integrate with fire alarm?

Yes, PA system must integrate with fire alarm for voice evacuation (EN54-16 standard). When fire panel activates, PA system automatically: 1) stops background music, 2) plays pre-recorded evacuation message in all zones, 3) turns all speakers to maximum volume, 4) continues message until fire panel is reset. This is life-safety critical function.