ZKTeco ZKABK902A-R/G emergency release button
- Model
- 9521
Emergency button with two 2NO/2NC/2COM contact sets: door release or an alarm signal, reset with the supplied key.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Dimensions
- 86 * 86 * 52 (mm) (±1mm) (L*W*H)
- Operating temperature
- -10°C to 55°C
Description
The ZKTeco ZKABK902A-R/G is a resettable emergency release button. A press on the white insert triggers the alarm or opens the door. After the emergency, the front cover is loosened with the supplied key: the alarm stops and the door locks again, as many times as needed.
- Two 2NO/2NC/2COM contact sets (normally open, normally closed, common): one for the lock power circuit, the other for the alarm.
- Contacts rated up to 3 A at 125–250 V AC.
- Fireproof housing, 86 × 86 × 52 mm.
- Operating range -10 to 55 °C, 0–95% relative humidity.
The button is linked to the locks and the alarm during fire alarm installation.
Specifications
| Access control interfaces | 2NO / 2NC / 2COM |
|---|
| Rated current | AC 125 to 250V, 3A |
|---|
| Operating humidity | 0% to 95% (relative humidity) |
|---|---|
| Dimensions | 86 * 86 * 52 (mm) (±1mm) (L*W*H) |
| Material | Fireproof Material |
| Operating temperature | -10°C to 55°C |
FAQ
What's the difference between addressable and conventional alarm buttons?
Addressable buttons – each button has unique ID number, fire panel knows exactly which button activated and where located (e.g. "3rd floor, east staircase"), 2-wire connection, more expensive, ideal for large buildings. Conventional buttons – buttons grouped into zones (e.g. "Zone 3 - 3rd floor"), panel knows only zone, not precise location, 4-wire connection, cheaper, ideal for small buildings. Recommendation: addressable – hotels, hospitals, shopping centers. Conventional – offices, shops, factories.
How often should fire alarm manual call points be tested?
Fire alarm manual call points must be tested regularly to ensure safety. Recommendations: 1) weekly visual inspection – ensure button not damaged, glass intact, LED indicator working. 2) monthly functional test – use test key (for resettable buttons) or press button (for single-use buttons) and ensure siren activated. 3) annual professional inspection – full check by certified technician. This is mandatory for fire safety standards compliance.
Where should fire alarm manual call points be installed?
Correct placement of fire alarm manual call points is critical for effective evacuation. Recommendations: 1) at evacuation exits – at all emergency exits, stairs, in corridors. 2) height – 1.2-1.5m from floor (easily accessible for everyone including children and disabled). 3) visibility – button must be visible and easily noticeable (red color, "FIRE" text). 4) distance – maximum 30-45m distance between buttons (person must reach button in 30 seconds). 5) protection – avoid locations where button can be damaged (high traffic, transport).
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.