Heiman HM-726N gas detector
- Model
- 9695
Natural gas (methane, CH4) detector with a siren of at least 70 dB, a warning light and a connection for a solenoid valve manipulator.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Detected gas
- Ch4
- Compatible devices
- Solenoid Valve Manipulator
- Power supply
- AC 100-240 V
- Sound level
- ≥70 dB/1 m Alarm
- Dimensions
- 70 × 102 × 30.9 mm
- Operating temperature
- 0 °C – +40 °C
Description
The Heiman HM-726N is a natural gas detector: the alarm is triggered by methane (CH4), the main component of mains gas. The alarm is a siren plus a flashing light, and a solenoid valve manipulator can be connected to shut off the gas when a leak is found.
- Detected gas: methane (CH4).
- Siren of at least 70 dB at 1 m, plus a warning light.
- Works with a solenoid valve manipulator.
- AC 100–240 V mains supply.
- 70 × 102 × 30.9 mm housing, works from 0 to 40 °C; CE marked.
Methane is lighter than air, so the detector goes high up in the room, near the boiler or cooker. LAGI picks the mounting point and connects the valve as part of fire alarm installation.
Specifications
| Certifications | CE |
|---|---|
| Detected gas | Ch4 |
| Alarm output | Audio and Flash alarm |
|---|
| Sound level | ≥70 dB/1 m Alarm |
|---|
| Compatible devices | Solenoid Valve Manipulator |
|---|
| Power supply | AC 100-240 V |
|---|
| Dimensions | 70 × 102 × 30.9 mm |
|---|---|
| Operating temperature | 0 °C – +40 °C |
FAQ
What's the difference between methane and propane detectors?
Methane detectors – detect natural gas (CH4, methane) supplied to homes through pipes, methane is lighter than air and rises up, so detector must be installed on ceiling or upper wall (20-30cm from ceiling), ideal for kitchens, boiler rooms, near gas stoves. Propane/LPG detectors – detect liquefied gas (C3H8 propane, C4H10 butane) stored in cylinders, propane is heavier than air and sinks down, so detector must be installed near floor at 20-30cm height, ideal for homes with LPG cylinders, camping, garages. Important: don't replace methane detector with propane detector and vice versa – they are not interchangeable.
Where should I install gas leak detectors?
Correct gas detector placement depends on gas type. Methane detectors (natural gas): 1) on ceiling or upper wall 20-30cm from ceiling. 2) 1-4m distance from gas appliance (stove, boiler, water heater). 3) don't install directly above stove (false alarms). 4) avoid windows, doors, ventilation openings. Propane/LPG detectors (liquefied gas): 1) near floor at 20-30cm height. 2) 1-4m distance from LPG cylinder or gas appliance. 3) don't install on floor (damage risk). General recommendations: on all floors minimum one detector, in kitchen mandatory, in boiler room mandatory, monthly testing (test button).
What should I do if gas leak detector triggers?
If gas leak detector sounds, take following measures immediately: 1) don't ignore – gas leak is life threat (explosion, fire, poisoning). 2) shut off gas – close main gas valve (usually at gas meter or on cylinder). 3) don't turn on/off electrical devices – any spark can cause explosion. 4) open windows and doors – ventilation to reduce gas concentration. 5) evacuation – evacuate all people and pets from building to open air. 6) call 112 – call emergency service from open air (not from building). 7) gas technician – gas technician must check all gas appliances, pipes and find leak source. Don't enter building until professional checks and confirms it's safe.