Heiman HM-726N gas detector

Model
9695

Natural gas (methane, CH4) detector with a siren of at least 70 dB, a warning light and a connection for a solenoid valve manipulator.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Detected gas
Ch4
Compatible devices
Solenoid Valve Manipulator
Power supply
AC 100-240 V
Sound level
≥70 dB/1 m Alarm
Dimensions
70 × 102 × 30.9 mm
Operating temperature
0 °C – +40 °C
All specifications

Description

The Heiman HM-726N is a natural gas detector: the alarm is triggered by methane (CH4), the main component of mains gas. The alarm is a siren plus a flashing light, and a solenoid valve manipulator can be connected to shut off the gas when a leak is found.

  • Detected gas: methane (CH4).
  • Siren of at least 70 dB at 1 m, plus a warning light.
  • Works with a solenoid valve manipulator.
  • AC 100–240 V mains supply.
  • 70 × 102 × 30.9 mm housing, works from 0 to 40 °C; CE marked.

Methane is lighter than air, so the detector goes high up in the room, near the boiler or cooker. LAGI picks the mounting point and connects the valve as part of fire alarm installation.

Specifications

General
CertificationsCE
Detected gasCh4
Access control
Alarm outputAudio and Flash alarm
Hardware
Sound level≥70 dB/1 m Alarm
Software and functions
Compatible devicesSolenoid Valve Manipulator
Power
Power supplyAC 100-240 V
Physical and environment
Dimensions70 × 102 × 30.9 mm
Operating temperature0 °C – +40 °C

FAQ

What's the difference between methane and propane detectors?

Methane detectors – detect natural gas (CH4, methane) supplied to homes through pipes, methane is lighter than air and rises up, so detector must be installed on ceiling or upper wall (20-30cm from ceiling), ideal for kitchens, boiler rooms, near gas stoves. Propane/LPG detectors – detect liquefied gas (C3H8 propane, C4H10 butane) stored in cylinders, propane is heavier than air and sinks down, so detector must be installed near floor at 20-30cm height, ideal for homes with LPG cylinders, camping, garages. Important: don't replace methane detector with propane detector and vice versa – they are not interchangeable.

Where should I install gas leak detectors?

Correct gas detector placement depends on gas type. Methane detectors (natural gas): 1) on ceiling or upper wall 20-30cm from ceiling. 2) 1-4m distance from gas appliance (stove, boiler, water heater). 3) don't install directly above stove (false alarms). 4) avoid windows, doors, ventilation openings. Propane/LPG detectors (liquefied gas): 1) near floor at 20-30cm height. 2) 1-4m distance from LPG cylinder or gas appliance. 3) don't install on floor (damage risk). General recommendations: on all floors minimum one detector, in kitchen mandatory, in boiler room mandatory, monthly testing (test button).

What should I do if gas leak detector triggers?

If gas leak detector sounds, take following measures immediately: 1) don't ignore – gas leak is life threat (explosion, fire, poisoning). 2) shut off gas – close main gas valve (usually at gas meter or on cylinder). 3) don't turn on/off electrical devices – any spark can cause explosion. 4) open windows and doors – ventilation to reduce gas concentration. 5) evacuation – evacuate all people and pets from building to open air. 6) call 112 – call emergency service from open air (not from building). 7) gas technician – gas technician must check all gas appliances, pipes and find leak source. Don't enter building until professional checks and confirms it's safe.

Need it installed?

LAGI will deliver, install and set up the equipment and provide warranty service afterwards.