Heiman HM-205 standalone heat detector

Model
9682

Class A1 heat detector with an alarm at 54–65 °C, an 85 dB siren and RF868 radio between detectors, up to 40 devices per system.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Sensor type
Thermistor
Alarm threshold
Class: A1; Alarms at temperature range: 54 °C to 65 °C
Maximum connected devices
40
Card frequency
868 MHz
Power supply
Power supply: 3 V sealed battery; Power supply mode: 10 years Battery Built-in
Wireless protocol
RF868
All specifications

Description

The Heiman HM-205 is a standalone class A1 heat detector with a radio link: the alarm goes off when the air heats up to 54–65 °C. Over RF868 radio, detectors join into one system of up to 40 devices.

  • Class A1: response between 54 and 65 °C, thermistor sensor.
  • Radio range 30 m indoors and 100 m in open space.
  • 85 dB siren at 3 m.
  • Built-in sealed 3 V battery rated for 10 years.
  • 86 mm diameter housing in ABS+PC, UL94 V0 flame retardant.
  • Works from 4 to 38 °C at up to 90 % humidity, non-condensing.

LAGI picks mounting points with the radio range in mind as part of fire alarm installation.

Specifications

General
Sensor typeThermistor
Alarm thresholdClass: A1; Alarms at temperature range: 54 °C to 65 °C
Capacity
Maximum connected devices40
Cards and codes
Card frequency868 MHz
Communication
Communication distance30 m indoors, 100 m in open spaces
Wireless protocolRF868
InterconnectionStandalone
Hardware
Sound level85 dB (at 3 m)
Power
Power supplyPower supply: 3 V sealed battery; Power supply mode: 10 years Battery Built-in
Physical and environment
DimensionsΦ86 × 41.50 mm
MaterialABS+PC, UL94 V0 fire retardant
Operating temperature4 °C – 38 °C
Operating humidity≤90%RH (non-condensing)

FAQ

What's the difference between heat and smoke detectors?

Smoke detectors – detect smoke particles in air, faster response (several minutes earlier), ideal for living rooms, bedrooms, corridors, but cause false alarms in kitchen (cooking), bathroom (steam), garage (dust). Heat detectors – detect temperature rise, don't react to smoke/steam/dust, slower response (several minutes later), ideal for kitchens, bathrooms, garages, warehouses. Recommendation: smoke detectors – bedrooms, corridors. Heat detectors – kitchen, bathroom, garage. Combination – best protection.

What is Rate-of-Rise (ROR) function in heat detector?

Rate-of-Rise (ROR) is function that detects rapid temperature rise over time. How it works: detector measures temperature every second and calculates rise rate. If temperature rises more than 8-10°C/min, detector triggers even if temperature hasn't reached fixed threshold (e.g. 57°C). This provides faster response than fixed temperature detectors. Example: room temperature 20°C → fire starts → temperature rises 20°C → 35°C → 50°C (in 30 seconds) → ROR detector triggers at 50°C, fixed detector triggers at 57°C (10 seconds later).

Where should I use heat detectors instead of smoke detectors?

Heat detectors are recommended for locations where smoke detectors cause false alarms: 1) kitchen – cooking produces smoke/steam, heat detector doesn't react. 2) bathroom – hot water steam causes false alarm in smoke detector. 3) garage – dust, car exhaust, heat detector more reliable. 4) warehouse – dusty environment, heat detector doesn't react to dust. 5) attic/basement – high humidity, temperature fluctuations. 6) industrial facilities – welding, cutting, dusty processes. Important: heat detectors should not be used in bedrooms – use smoke detectors.

Need it installed?

LAGI will deliver, install and set up the equipment and provide warranty service afterwards.