Heiman HM-5HA standalone heat detector
- Model
- 9683
Standalone heat detector with a siren of at least 85 dB and a built-in 10-year battery, for rooms where steam or smoke would trip a smoke detector.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Sensor type
- Thermistor
- Sensor life
- 10 years
- Power supply
- Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Built-in
- Wireless protocol
- RF433, RF868
- Interconnection
- Standalone
- Sound level
- ≥85 dB (at 3 m)
Description
The Heiman HM-5HA is a standalone heat detector: temperature sensor, siren and battery in one housing. Heat detectors go where steam, cooking fumes or exhaust would cause false alarms from a smoke detector: kitchens, garages, boiler rooms.
- Thermistor sensor rated for 10 years.
- Siren of at least 85 dB at 3 m, red LED indicator.
- RF433 or RF868 radio, depending on the version.
- Built-in 3 V lithium battery rated for 10 years.
- Ceiling mounting, Φ99.5 × 35 mm housing.
- Works from 0 to 55 °C at up to 95 % humidity, non-condensing; CE marked.
Which rooms get heat detectors and which get smoke detectors is decided during fire alarm installation.
Specifications
| Certifications | CE |
|---|---|
| Sensor type | Thermistor |
| Sensor life | 10 years |
| Wireless protocol | RF433, RF868 |
|---|---|
| Interconnection | Standalone |
| Sound level | ≥85 dB (at 3 m) |
|---|---|
| Alarm indication | Red LED indicator |
| Power supply | Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Built-in |
|---|
| Dimensions | Φ99.5 × 35 mm |
|---|---|
| Mounting | Ceiling |
| Operating temperature | 0 °C – +55 °C |
| Operating humidity | ≤95%RH (non-condensing) |
FAQ
What's the difference between heat and smoke detectors?
Smoke detectors – detect smoke particles in air, faster response (several minutes earlier), ideal for living rooms, bedrooms, corridors, but cause false alarms in kitchen (cooking), bathroom (steam), garage (dust). Heat detectors – detect temperature rise, don't react to smoke/steam/dust, slower response (several minutes later), ideal for kitchens, bathrooms, garages, warehouses. Recommendation: smoke detectors – bedrooms, corridors. Heat detectors – kitchen, bathroom, garage. Combination – best protection.
What is Rate-of-Rise (ROR) function in heat detector?
Rate-of-Rise (ROR) is function that detects rapid temperature rise over time. How it works: detector measures temperature every second and calculates rise rate. If temperature rises more than 8-10°C/min, detector triggers even if temperature hasn't reached fixed threshold (e.g. 57°C). This provides faster response than fixed temperature detectors. Example: room temperature 20°C → fire starts → temperature rises 20°C → 35°C → 50°C (in 30 seconds) → ROR detector triggers at 50°C, fixed detector triggers at 57°C (10 seconds later).
Where should I use heat detectors instead of smoke detectors?
Heat detectors are recommended for locations where smoke detectors cause false alarms: 1) kitchen – cooking produces smoke/steam, heat detector doesn't react. 2) bathroom – hot water steam causes false alarm in smoke detector. 3) garage – dust, car exhaust, heat detector more reliable. 4) warehouse – dusty environment, heat detector doesn't react to dust. 5) attic/basement – high humidity, temperature fluctuations. 6) industrial facilities – welding, cutting, dusty processes. Important: heat detectors should not be used in bedrooms – use smoke detectors.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.