Heiman HM-628PH standalone smoke detector

Model
9667

Standalone optical smoke detector powered by a 9 V battery, rated for 1 or 5 years depending on the version, with a siren of at least 85 dB.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Sensor type
Photoelectric
Power supply
Power supply: DC 9 V Battery; Power supply mode: 1 year Battery; 5 years Battery
Interconnection
Standalone
Sound level
≥85 dB (at 3 m)
Dimensions
Φ95.6 × 43.2 mm
Operating temperature
0 °C – +55 °C
All specifications

Description

The Heiman HM-628PH is a standalone optical smoke detector powered by a 9 V battery. Sensor and siren share one housing, so no wiring or control panel is needed.

  • Photoelectric sensor, triggered by smoke particles in the chamber.
  • Siren of at least 85 dB at 3 m.
  • 9 V battery rated for 1 year or 5 years, depending on the version.
  • 95.6 mm across, 43.2 mm high.
  • Works from 0 to 55 °C at up to 95 % humidity, non-condensing.
  • Meets EN14604:2005/AC:2008, DBI certified.

LAGI chooses detector positions in a flat or house as part of fire alarm installation.

Specifications

General
CertificationsEN14604:2005/AC:2008, DBI
Sensor typePhotoelectric
Communication
InterconnectionStandalone
Hardware
Sound level≥85 dB (at 3 m)
Power
Power supplyPower supply: DC 9 V Battery; Power supply mode: 1 year Battery; 5 years Battery
Physical and environment
DimensionsΦ95.6 × 43.2 mm
Operating temperature0 °C – +55 °C
Operating humidity≤95%RH (non-condensing)

FAQ

What's the difference between optical and ionization smoke detectors?

Optical (photoelectric) detectors – use LED light and photodiode, detect smoke particles by light scattering, ideal for slow smoldering fires (furniture, fabric), fewer false alarms, safe (no radioactive material), recommended for residential homes. Ionization detectors – use radioactive source (Americium-241), detect invisible smoke particles, ideal for fast flaming fires (paper, gasoline), faster response, but more false alarms. Recommendation: optical – residential homes, offices. Ionization – kitchens, warehouses. Dual sensor – best option (both fire types).

Where should I install smoke detectors?

Correct smoke detector placement is critical for effective protection. Recommendations: 1) in all bedrooms – detector must be in all bedrooms and in corridor near bedrooms. 2) on all floors – minimum one detector per floor including basement and attic. 3) on ceiling – detector must be installed on ceiling or on wall 10-30cm from ceiling (smoke rises up). 4) avoid – kitchen (false alarms when cooking), bathroom (steam), windows/doors (air flow). 5) distance – maximum 10-15m distance between detectors. 6) testing – monthly press test button and ensure siren works.

How often should I replace smoke detector battery?

Smoke detector battery life depends on type. Standard 9V battery – 6-12 months, detector beeps when battery weakens (one beep every 30-60 seconds), replace immediately. 10-year lithium battery – 10 years, built into detector, no replacement needed, after 10 years replace entire detector. AC power (220V) + backup battery – backup battery 1-2 years. Recommendation: replace battery twice per year (when changing clocks), replace entire detector after 10 years (sensor ages and loses accuracy).