Heiman HS1SA standalone smoke detector
- Model
- 9670
Compact standalone optical smoke detector, 60 × 60 × 49.2 mm, with a replaceable 10-year lithium battery and a siren of at least 85 dB.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Sensor type
- Photoelectric
- Power supply
- Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Replaceable
- Interconnection
- Standalone
- Sound level
- ≥85 dB (at 3 m)
- Dimensions
- 60 × 60 × 49.2 mm
- Operating temperature
- -10 °C – +55 °C
Description
The Heiman HS1SA is a compact standalone smoke detector: a 60 × 60 × 49.2 mm housing with an optical sensor, siren and lithium battery inside. No wiring or control panel, for a flat, house or office.
- Photoelectric sensor, triggered by smoke particles.
- Siren of at least 85 dB at 3 m.
- 3 V lithium battery rated for 10 years, replaceable.
- Works from -10 to 55 °C at up to 95 % humidity, non-condensing.
- Meets EN14604:2005/AC:2008; TÜV Rheinland, DBI and FCC certified.
LAGI plans the detector layout room by room as part of fire alarm installation.
Specifications
| Certifications | EN14604:2005/AC:2008, TÜV Rheinland, DBI, FCC |
|---|---|
| Sensor type | Photoelectric |
| Interconnection | Standalone |
|---|
| Sound level | ≥85 dB (at 3 m) |
|---|
| Power supply | Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Replaceable |
|---|
| Dimensions | 60 × 60 × 49.2 mm |
|---|---|
| Operating temperature | -10 °C – +55 °C |
| Operating humidity | ≤95%RH (non-condensing) |
FAQ
What's the difference between optical and ionization smoke detectors?
Optical (photoelectric) detectors – use LED light and photodiode, detect smoke particles by light scattering, ideal for slow smoldering fires (furniture, fabric), fewer false alarms, safe (no radioactive material), recommended for residential homes. Ionization detectors – use radioactive source (Americium-241), detect invisible smoke particles, ideal for fast flaming fires (paper, gasoline), faster response, but more false alarms. Recommendation: optical – residential homes, offices. Ionization – kitchens, warehouses. Dual sensor – best option (both fire types).
Where should I install smoke detectors?
Correct smoke detector placement is critical for effective protection. Recommendations: 1) in all bedrooms – detector must be in all bedrooms and in corridor near bedrooms. 2) on all floors – minimum one detector per floor including basement and attic. 3) on ceiling – detector must be installed on ceiling or on wall 10-30cm from ceiling (smoke rises up). 4) avoid – kitchen (false alarms when cooking), bathroom (steam), windows/doors (air flow). 5) distance – maximum 10-15m distance between detectors. 6) testing – monthly press test button and ensure siren works.
How often should I replace smoke detector battery?
Smoke detector battery life depends on type. Standard 9V battery – 6-12 months, detector beeps when battery weakens (one beep every 30-60 seconds), replace immediately. 10-year lithium battery – 10 years, built into detector, no replacement needed, after 10 years replace entire detector. AC power (220V) + backup battery – backup battery 1-2 years. Recommendation: replace battery twice per year (when changing clocks), replace entire detector after 10 years (sensor ages and loses accuracy).
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.