Heiman S1 standalone smoke detector
- Model
- 9671
Standalone optical smoke detector certified to the US standard UL217, 9th edition, with RF915 radio and a replaceable 10-year battery.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Sensor type
- Photoelectric
- Alarm threshold
- 1.625%/FT ± 0.625%/FT
- Power supply
- Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Replaceable
- Wireless protocol
- RF915
- Interconnection
- Standalone
- Sound level
- ≥85 dB (at 3 m)
Description
The Heiman S1 is a standalone optical smoke detector certified to UL217, 9th edition, the US standard for smoke alarms. The housing is small: 70 mm across and 37 mm high.
- Alarm threshold 1.625 %/ft ± 0.625 %/ft: how much smoke dims light over each foot of path.
- RF915 radio, in the 915 MHz band.
- Siren of at least 85 dB at 3 m.
- Replaceable 3 V lithium battery rated for 10 years.
- Works from 4.4 to 37.8 °C (40–100 °F) at up to 95 % humidity, non-condensing.
- Certified to UL217 9th edition, ETL Listed (Intertek).
LAGI designs detector positions in a home as part of fire alarm installation.
Specifications
| Certifications | UL217 9th edition, ETL Listed (Intertek) |
|---|---|
| Sensor type | Photoelectric |
| Alarm threshold | 1.625%/FT ± 0.625%/FT |
| Wireless protocol | RF915 |
|---|---|
| Interconnection | Standalone |
| Sound level | ≥85 dB (at 3 m) |
|---|
| Power supply | Power supply: DC3 V (Lithium Battery); Power supply mode: 10 years Battery Replaceable |
|---|
| Dimensions | Φ70 × 37 mm |
|---|---|
| Operating temperature | 40°F (4.4 °C) to 100°F (37.8 °C) |
| Operating humidity | ≤95%RH (non-condensing) |
FAQ
What's the difference between optical and ionization smoke detectors?
Optical (photoelectric) detectors – use LED light and photodiode, detect smoke particles by light scattering, ideal for slow smoldering fires (furniture, fabric), fewer false alarms, safe (no radioactive material), recommended for residential homes. Ionization detectors – use radioactive source (Americium-241), detect invisible smoke particles, ideal for fast flaming fires (paper, gasoline), faster response, but more false alarms. Recommendation: optical – residential homes, offices. Ionization – kitchens, warehouses. Dual sensor – best option (both fire types).
Where should I install smoke detectors?
Correct smoke detector placement is critical for effective protection. Recommendations: 1) in all bedrooms – detector must be in all bedrooms and in corridor near bedrooms. 2) on all floors – minimum one detector per floor including basement and attic. 3) on ceiling – detector must be installed on ceiling or on wall 10-30cm from ceiling (smoke rises up). 4) avoid – kitchen (false alarms when cooking), bathroom (steam), windows/doors (air flow). 5) distance – maximum 10-15m distance between detectors. 6) testing – monthly press test button and ensure siren works.
How often should I replace smoke detector battery?
Smoke detector battery life depends on type. Standard 9V battery – 6-12 months, detector beeps when battery weakens (one beep every 30-60 seconds), replace immediately. 10-year lithium battery – 10 years, built into detector, no replacement needed, after 10 years replace entire detector. AC power (220V) + backup battery – backup battery 1-2 years. Recommendation: replace battery twice per year (when changing clocks), replace entire detector after 10 years (sensor ages and loses accuracy).