Heiman HM-638TH combined smoke and carbon monoxide detector

Model
9681

Smoke and carbon monoxide detector in one housing: 100–240 V mains power, a built-in 10-year backup battery and an optional hard-wired interlink.

On order

Price on request

Send a request. A manager will name the price and the delivery time during working hours.

Key specifications

Sensor type
Photoelectric
Power supply
Power supply: AC100-240 V with backup Sealed battery; Power supply mode: 10 years Battery Built-in
Interconnection
Standalone/Hardwire Inter-linked (optional)
Sound level
≥85 dB (at 3 m)
Dimensions
143 × 143 × 39 mm
Operating temperature
4.4 °C – 37.8 °C (40°F~100°F)
All specifications

Description

The Heiman HM-638TH is a combined smoke and carbon monoxide detector: two hazards, fire and carbon monoxide from a boiler or stove, covered by one device on the ceiling or wall.

  • Optical (photoelectric) smoke sensor, siren of at least 85 dB at 3 m.
  • AC 100–240 V mains supply with a built-in sealed backup battery rated for 10 years.
  • Standalone operation or optional hard-wired interlink.
  • 143 × 143 × 39 mm housing, wall or ceiling mounting on a bracket.
  • Works from 4.4 to 37.8 °C at up to 95 % humidity, non-condensing.
  • Meets EN14604:2005/AC:2008.

A combined detector suits homes where a boiler or stove sits close to living rooms: one mounting point instead of two. LAGI plans the mains wiring and positions as part of fire alarm installation.

Specifications

General
CertificationsEN14604:2005/AC:2008
Sensor typePhotoelectric
Communication
InterconnectionStandalone/Hardwire Inter-linked (optional)
Hardware
Sound level≥85 dB (at 3 m)
Power
Power supplyPower supply: AC100-240 V with backup Sealed battery; Power supply mode: 10 years Battery Built-in
Physical and environment
Dimensions143 × 143 × 39 mm
MountingInstallation positions: Wall mounting/Ceiling mounting; Mounting type: Mounting bracket
Operating temperature4.4 °C – 37.8 °C (40°F~100°F)
Operating humidity≤95%RH (no condensation)

FAQ

Why is a combination smoke and CO detector needed?

A combination smoke and CO detector is needed because it protects from two different threats: 1) smoke (fire) – fire produces smoke, smoke inhalation is the main cause of death in fires (80% of fire victims die from smoke inhalation, not from flames), smoke detector detects smoke → siren → people evacuate → life protection. 2) carbon monoxide (CO) – CO is an invisible, odorless, tasteless gas (invisible killer), CO is produced during incomplete combustion (gas heater, stove, generator, car), CO inhalation causes headache, nausea, confusion, heart attack, death (30-60 minutes at 400ppm CO), CO detector detects CO → siren → people evacuate → life protection. Why combination – fire and CO often occur simultaneously (fire produces CO), separate detectors: smoke detector (detects smoke, but not CO) + CO detector (detects CO, but not smoke) = 2 devices, 2 batteries, 2 installations, 70-110 GEL. Combination detector: detects smoke and CO = 1 device, 1 battery, 1 installation, 50-80 GEL → savings 20-30 GEL + simpler + more aesthetic. Recommendation: if you have gas heating, stove, generator → combination detector mandatory (smoke + CO), if no gas → smoke detector sufficient.

Where to install a combination smoke and CO detector?

Proper installation of a combination smoke and CO detector is critical for effective detection: where to install – bedroom: install 1 detector in each bedroom (on ceiling, center), people sleep → don't sense smoke/CO → detector will wake them. Hallway: install 1 detector in hallway (on ceiling, center), hallway connects all rooms → smoke/CO will spread to hallway. Living room: install 1 detector in living room (on ceiling, center), people often in living room → detector will warn them. Kitchen: don't install detector in kitchen (false alarms during cooking), install detector 3-5m away from kitchen. Bathroom: don't install detector in bathroom (false alarms from steam). Gas heater/stove: install detector in same room as gas heater/stove (CO risk), 1-3m distance from heater. Basement/garage: install detector in basement/garage (CO risk from car, generator). How to install – on ceiling: install on ceiling (center), smoke and CO rise up → detector on ceiling detects first. On wall: if ceiling installation impossible → install on wall (15-30cm from ceiling). Recommendation: minimum 1 detector per floor, 1 detector in each bedroom, 1 detector in hallway, 1 detector in living room → complete coverage.

How to know the combination detector works and when to replace?

Regular testing and maintenance of the combination detector is critical for reliable operation: how to know it works – monthly test: press test button (1× per month), detector emits siren (85dB) → detector works. LED indicator: green LED flashes (every 30-60 seconds) → detector works, red LED → alarm (smoke or CO), yellow LED → battery low or sensor faulty. Battery notification: detector emits beep (every 30-60 seconds) → battery low → replace battery. When to replace – battery: replace battery every 1-2 years (9V or AA), replace battery when detector beeps. Smoke sensor: smoke sensor works 10 years → replace detector after 10 years. CO sensor: CO sensor works 7-10 years → replace detector after 7-10 years. Entire detector: replace entire detector after 7-10 years (CO sensor lifespan), date written on back of detector. Cleaning: clean detector 1× every 6 months (dust, cobwebs), use vacuum (low power) or compressed air. Recommendation: monthly test (press test button), cleaning every 6 months, battery replacement every 1-2 years, detector replacement every 7-10 years → reliable protection.