ZKTeco DM10 relay module
- Model
- 9537
Lock control module for ZKTeco access control devices with RS485: no user data is stored in the module, and the lock and exit button are wired to the module.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Description
The ZKTeco DM10 is a relay module for lock control, made for access control devices with an RS485 interface such as the F18, Horus and C2-260. No user data is recorded in the DM10: all data is processed in the access control device, and the module is used for lock control only.
- RS485 link to the access control device.
- Connections for two Wiegand readers.
- 12 V power in and out.
- Lock sensor and exit button connections.
- One auxiliary input and one auxiliary output (AUX IN, AUX OUT).
RS485 is a wired interface for linking devices over long cable runs. The access device – module – lock chain is built during access control installation.
Specifications
| Main features | RS485 Communication2 Wiegand Readers12V Power In & Out1 Lock Sensor, 1 Exit Button1 AUX IN, 1 AUX OUT |
|---|
Used in solutions
FAQ
Why is relay needed in access control system?
Relay needed for several reasons: controller protection – access controller output is low power (100-200mA), electronic locks require high current (1-3A), if directly connect lock to controller – controller will burn. Electrical noise isolation – electronic locks create electrical noise (EMI), relay isolates controller from this noise. Multiple lock management – with one controller output can manage multiple locks through relays. Fail-Safe/Fail-Secure – relay allows changing lock logic.
What's the difference between NO and NC relay contacts?
NO (Normally Open) contacts – normally open, when relay off contacts open (no connection), when relay turns on contacts close (connection appears). Used for Fail-Secure locks – during power outage lock is closed. NC (Normally Closed) contacts – normally closed, when relay off contacts closed (connection exists), when relay turns on contacts open (connection breaks). Used for Fail-Safe locks – during power outage lock is open (fire safety).
How to connect relay to access controller?
Relay connection: controller output → relay input – connect controller Relay Output (usually NO/COM terminals) to relay coil (Coil Input, usually + and - terminals). Power supply → relay – connect 12V/24V DC power supply to relay (in some models power comes from controller). Relay output → electronic lock – connect relay NO/NC contacts to electronic lock and power supply. When controller sends signal (card read) → relay turns on → lock opens.
Need it installed?