ZKTeco EX0808 I/O expansion module
- Model
- 9538
Board with 8 auxiliary inputs and 8 outputs for ZKTeco inBio Pro and C3 Pro controllers; RS485 or OSDP link, 12 V DC power.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Communication interfaces
- RS485 and OSDP (version 2.1.7)
- Dimensions
- 160mm * 106mm (6.29in * 4.17in) (L*W)
- Power supply
- 12V DC 300mA
- Operating temperature
- 0°C to 45°C (32°F to 113°F)
Description
The ZKTeco EX0808 is an I/O expansion module: 8 auxiliary (AUX) inputs and 8 outputs on one board, for sites where the controller's own inputs and outputs are not enough.
The EX0808 is made for ZKTeco inBio Pro and C3 Pro controllers and the ZKBioSecurity software. Each inBio Pro or C3 Pro controller takes up to 8 EX0808 boards, for up to 64 extra inputs and 64 outputs. The board can also be switched to OSDP and connected to other controllers that support OSDP. OSDP is an open protocol for data exchange between access control devices over an RS485 line.
- Form-C (SPDT) relays: 5 A at 30 V DC or 10 A at 30 V AC.
- RS485 and OSDP (version 2.1.7), 9600 bps.
- RS485 address set with a DIP switch.
- 12 V DC, 300 mA power, 3.6 W consumption.
- 160 × 106 mm, 0.2 kg.
- Operating range 0 to 45 °C, 20–80 % humidity.
A metal case for the board is available separately. The number of boards and the split of inputs and outputs across the site are worked out during access control installation.
Specifications
| Auxiliary inputs | 8 |
|---|---|
| Auxiliary outputs | 8 |
| Lock relay output | 3Form-C Relays-SPDT 5A@ 30V DC or 10A @ 30V AC |
| Communication interfaces | RS485 and OSDP (version 2.1.7) |
|---|---|
| Baud rate | 9,600bps |
| RS485 address | Set by the DIP switch |
| Power consumption | 3.6W @ 12V DC 300mA |
|---|---|
| Power supply | 12V DC 300mA |
| Operating humidity | 20% to 80% |
|---|---|
| Net weight | 0.2kg (0.44lbs) |
| Dimensions | 160mm * 106mm (6.29in * 4.17in) (L*W) |
| Operating temperature | 0°C to 45°C (32°F to 113°F) |
Used in solutions
FAQ
Why is relay needed in access control system?
Relay needed for several reasons: controller protection – access controller output is low power (100-200mA), electronic locks require high current (1-3A), if directly connect lock to controller – controller will burn. Electrical noise isolation – electronic locks create electrical noise (EMI), relay isolates controller from this noise. Multiple lock management – with one controller output can manage multiple locks through relays. Fail-Safe/Fail-Secure – relay allows changing lock logic.
What's the difference between NO and NC relay contacts?
NO (Normally Open) contacts – normally open, when relay off contacts open (no connection), when relay turns on contacts close (connection appears). Used for Fail-Secure locks – during power outage lock is closed. NC (Normally Closed) contacts – normally closed, when relay off contacts closed (connection exists), when relay turns on contacts open (connection breaks). Used for Fail-Safe locks – during power outage lock is open (fire safety).
How to connect relay to access controller?
Relay connection: controller output → relay input – connect controller Relay Output (usually NO/COM terminals) to relay coil (Coil Input, usually + and - terminals). Power supply → relay – connect 12V/24V DC power supply to relay (in some models power comes from controller). Relay output → electronic lock – connect relay NO/NC contacts to electronic lock and power supply. When controller sends signal (card read) → relay turns on → lock opens.