Heiman HM-920 alarm control panel
- Model
- 9692
Control panel for a conventional fire alarm with 2 or 4 zones: audible and visual alarm on the panel, relay output, backup batteries.
On order
Price on request
Send a request. A manager will name the price and the delivery time during working hours.
Key specifications
- Power supply
- AC220 V±15%/50 Hz
- Dimensions
- 300 × 210 × 100 mm
- Zones
- 2 zones / 4 zones
Description
The Heiman HM-920 is an alarm control panel for a conventional fire alarm system. Smoke and heat detectors connect to the panel over 2-wire loops, and alarms are shown by zone: 2 or 4 zones, depending on the version.
In a conventional system an alarm comes from a whole zone (loop) rather than from a numbered detector, so a building is split into zones that make the source of a fire quick to find.
- Alarm: audible and visual signal on the panel, plus a relay output for external devices.
- Supply AC 220 V ±15 %, 50 Hz; backup from two 12 V, 2.6 Ah batteries.
- Current at 24 V: under 120 mA on standby, under 180 mA in alarm.
- Wall mounting, 300 × 210 × 100 mm housing.
- Works from -10 to 60 °C at 5–95 % humidity.
Splitting the building into zones and sizing the loops are part of fire alarm installation.
Specifications
| Alarm output | Audio & flash alarm; Relay output |
|---|
| Power supply | AC220 V±15%/50 Hz |
|---|---|
| Backup battery | DC12 V/2.6Ahx2 |
| Standby current | <120 mA@24 V |
| Alarm current | <180 mA@24 V |
| Zones | 2 zones / 4 zones |
|---|
| Dimensions | 300 × 210 × 100 mm |
|---|---|
| Mounting | Wall mounted |
| Wiring | 2 wire |
| Operating environment | -10 °C – 60 °C (5% – 95%RH) |
FAQ
What's the difference between conventional and addressable fire systems?
Conventional systems – detectors grouped into zones (e.g. "Zone 3 - 3rd floor"), panel shows only zone, not exact detector, 4-wire cabling (2 wire power + 2 wire signal), cheaper, simple installation, ideal for small/medium buildings (4-32 zones). Addressable systems – each detector has unique ID, panel shows exact detector (e.g. "Detector #47"), 2-wire Loop cabling, more expensive, complex programming, ideal for large buildings (128-512 addresses). Recommendation: conventional – small offices, shops, residential houses. Addressable – hotels, hospitals, shopping centers.
What is zone in conventional fire system?
Zone is group of detectors representing specific area in building. How it works: all detectors in one zone connect to one 4-wire cable that goes to zone terminal on panel. When any detector in this zone triggers, panel shows "Zone 3 alarm", but doesn't know which specific detector. Zone planning: 1) geographical – one zone = one floor or one wing. 2) functional – one zone = one type of space (e.g. all bedrooms). 3) size – one zone maximum 20-30 detectors, maximum 2000m² area. Example: 3-floor building → Zone 1 (1st floor), Zone 2 (2nd floor), Zone 3 (3rd floor), Zone 4 (basement).
What is EOL (End-of-Line) resistor and why is it needed?
EOL (End-of-Line) resistor is small resistor (usually 4.7kΩ or 10kΩ) installed in last detector of zone in conventional fire systems. Why needed: EOL resistor allows panel to monitor zone cable integrity. How it works: panel sends small current into zone cable and measures resistance. 1) normal state – panel sees EOL resistor → zone OK. 2) fire – detector closes contact → resistance changes → panel shows "Zone 3 alarm". 3) cable break – EOL resistor not visible → panel shows "Zone 3 fault". 4) short-circuit – resistance very low → panel shows "Zone 3 short-circuit". This ensures system always works and is not damaged.
Need it installed?
LAGI will deliver, install and set up the equipment and provide warranty service afterwards.